![Wood-mizer LT70-R Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/wood-mizer/lt70-r/lt70-r_safety-operation-maintenance-and-parts-manual_994570025.webp)
Accuset 2 Troubleshooting
Control Lights (Single-Axis)
Accuset 2 Troubleshooting
60AS2-R07doc032519
2-5
2
See Figure 2-5. DC Only (Rev. A.00 - A.02):
Diagnostic lights are provided on the motor
control module. When the saw head is in neutral (not moving up or down), the status light
is green and the brake light is red. When the up/down drum switch is moved to the up
position, the brake light is off and the switch and motor lights are green. With the up/down
drum switch in the down position, the brake light is off and the switch and motor lights are
red. If an error occurs, the status or sensor light will turn red. A corresponding error mes-
sage will be displayed to provide more detail about the problem.
FIG. 2-5
Switch Motor Brake
Status Sensor
Diagnostics
Switch Motor Brake
Status Sensor
Diagnostics
SM0342
Switch Motor Brake
Status Sensor
Diagnostics
Switch Motor Brake
Status Sensor
Diagnostics
Saw Head
Neutral
Saw Head
Up
Saw Head
Down
Diagnostic
Lights