Setup & Operation
Control Setup
Setup & Operation
60AS2-R07doc032519
1-8
1
Units.
This setting allows you to choose what unit of measure to use for your Blade
Height and Increment Settings. The default value is Fractional Inches (1/32”). You can
change the Unit Of Measure to Decimal Inches (.0313”) or Millimeters (1 mm). Push the
Save button to store the new Unit Of Measure setting. To return to the previously stored
Unit Of Measure, push Exit and turn the key switch to the off (#0) position.
See Figure 1-7.
PID (Proportional - Integral - Differential) Values.
These settings allow a technician to
diagnose and fine-tune the Accuset control for various environmental factors. These set-
tings are made at the factory and should not normally need adjusting by the operator.
See Table 1-2.
The factory default PID value settings are shown below. Alternate set-
tings are provided for use with LT70E25 electric sawmills.
After making the desired PID Value adjustments, push the Save button and go to the
desired Accuset mode. Test how the changes affect Accuset performance. If the new set-
tings cause undesirable results, reset Accuset to the factory defaults (
).
FIG. 1-7
Value
Factory Default
Alternate for LT70 E25
Up Ticks
1
5
Up Distance
7500
17000
Up Minimum
50
2
Down Ticks
1
5
Down Distance
5000
17000
Down Minimum
50
2
TABLE 1-2
3H0989-6
UNIT OF MEASURE
Decimal
Fractional
Millimeter
Exit
6 - 3/4