Maintenance & Alignment
EG300 Safety Devices Inspection (CE version only)
6
6-15
EGdoc022715
Maintenance & Alignment
Push the E-STOP button located on the control box. The motor should stop. It should not be
possible to restart the motor until the E-STOP is released.
2. Housing E-STOP Button Circuit Inspection
Start the main motor;
Push the E-STOP button located on the edger housing. The motor should stop. It should not be
possible to restart the motor until the E-STOP is released.
3. Cover Safety Switch Circuit Inspection - Cover #1
Start the main motor;
Open the cover #1;
The main motor should stop;
Try to start the motor using the START button. It should not be possible to start the motor.
Close the cover #1;
The motor should remain turned off.
3. Cover Safety Switch Circuit Inspection - Cover #2
FIG. 6-10