SETWORKS OPERATION (EG300 ce Only)
Start-up settings of the controller
4
4-3
EGdoc022715
SETWORKS OPERATION (EG300 ce Only)
See Pic. 4-2.
Press
to save the entered divider value.
1. Auto-calibration
This function should be used in case of: replacement of any component of the blades width setting
system, motor or after lubrication of the chains and other moving elements or when significant cutting
variances are observed;
Switch on the edger by turning the main switch to ON position. and wait until the text “TBS-01”
disappears.
Using
buttons set the blades to 180 mm (7.07") width.
Press and hold down
. After a while - the text “
Aut
” will appear on the displays.
The controller is ready for auto-calibration.
PIC. 4-2
TBS 01 Setworks
Real Size (mm)
Check real size
AUTO
CAL.
SAVE
SET
ABCDE
Position Size (mm)
ENTER
A
B
C
D
E
SET
REAL SIZE
SAVE
AUTO
CAL.
Содержание EE20S-EMR
Страница 1: ......
Страница 2: ......
Страница 34: ...OPERATION Edger Setup 3 3 12 EGdoc022715 Operation are equal FIG 3 11 FIG 3 12 BPDQXDOV WE A A B B ...
Страница 37: ...OPERATION Machine Start Operation EGdoc022715 3 15 3 FIG 3 13 EG250 CONTROL PANEL 0 1 tb0089 ...
Страница 153: ...DC Electromagnetic Brake ce only Service DC Electromagnetic Brake ce only EAdoc022715 11 3 11 ...
Страница 154: ...DC Electromagnetic Brake ce only Service 11 11 4 EAdoc022715 DC Electromagnetic Brake ce only ...
Страница 155: ...Laser Information Specifications MHdoc022715 13 1 13 SECTION 12 LASER INFORMATION ...
Страница 156: ...Laser Information 13 13 2 MHdoc022715 Specifications ...
Страница 157: ...Laser Information Specifications MHdoc022715 13 3 13 ...