Operation
Preliminary Setup
Operation
SISdoc052814
2-4
2
2.3
Preliminary Setup
1.
Clean the machine as needed with a solution of 1 part liquid Dawn detergent to 9 parts
water. Use an air hose to blow any dust or debris from the blade clamp and up/down com-
ponents.
WARNING!
Never use WD-40 or any other non-specified
lubricant to clean the machine.
Keep liquid away from the sensor assembly.
2.
Make sure the voltage selector plate is set properly before turning on electrical power to
the setter.
3.
Plug the power cord in the socket at the rear of the setter.
4.
Locate the air assembly at the rear right side of the setter. Connect the incoming air sup-
ply line to the fitting. Make sure the air gauge indicates 60 P.S.I. Adjust the pressure if
needed. To adjust the pressure, lift the black cap located behind the air gauge. Turn the
cap clockwise to increase pressure, turn the cap counterclockwise to decrease pressure.
Push the cap down to secure when adjustment is complete.