Setup & Operation
Routine Maintenance Schedule
4-3
DS12doc060917
Setup & Operation
4
Gauge Assembly Adjustment
The gauge assemblies are installed and properly adjusted at the factory. If it is necessary,
use the gauge strip to adjust the gauge assemblies as described below.
Pull the blade clamp lever open and flip the index arm up. Turn the feed handle counter-
clockwise (or push and hold the Auto Feed option START - JOG button) to advance the
setter until the setter assemblies open.
Install the gauge strip in the setter assembly. Turn the feed handle counterclockwise (or
push and hold the AUTO FEED option START - JOG button) to advance the setter until
the setter assemblies start to close. Stop the setter when the setter assemblies are closed
but the setter pusher does not contact the gauge strip. Make sure the gauge strip spacers
are aligned with the gauge foot.
See Figure 4-3.
Loosen the set screw securing the gauge assembly to the setter assembly and pull the
gauge assembly slightly out to remove any pressure on the gauge foot. Unlock the dial
lock, adjust the setter gauge bezels to -.003 and lock the dial lock. Reinstall the gauge
assembly to the setter assembly so that the gauge foot touches the gauge strip spacer
and the gauge needle reads 0. Tighten the set screw to secure the gauge assembly in
place. Repeat the procedure for the other gauge assembly, if necessary. Install the blade
to the toothsetter and perform the calibration procedure to make sure the gauge assem-
blies are adjusted properly (
See Section 3.3 Dual Setter Calibration
).
FIG. 4-3
DS0001-34
Set Screw
Gauge Strip
Spacer (2)
Gauge Foot
Gauge
Assembly