Operation & Maintenance
Toothsetter Operation
3
3-8
TSdoc051122
Operation & Maintenance
3.4
Toothsetter Operation
1. Set the blade.
Measure set by clamping the blade between the back clamping plate and
the spring-loaded pins on the front clamping plate. Remember set should not vary more
than (±)0.001 from one tooth to the next.
To add set,
clamp in further on the blade. This brings the setting contact point against the
tooth. The amount you will need to bend the tooth forward to get the desired set will vary.
Recheck set and adjust as needed.
NOTE:
If the clamp locks before you have added enough set, adjust the setting contact
point in.
DO NOT
adjust the clamp nut.
To decrease set,
bend the tooth back with the slot in the correction tool provided.
Recheck set and adjust as needed.
Slide the blade to the right (or left) until the third tooth from the one just set comes in front
FIG. 3-5
SM0309PL_B