Operation & Maintenance
Toothsetter Adjustments
3
3-4
TSdoc051122
Operation & Maintenance
See Figure 3-2.
1. Adjust the blade rest screws.
Rest the blade evenly on the two blade rest bolts on each
side of the clamp. Adjust the rest screws until the gullet of the blade lies just above the top
of the clamp plates. (Deburring will remove burrs from the back side of the teeth, but may
not remove burrs from the gullet area. Keeping the gullet out of the clamp assembly helps
to assure accurate readings.)
2. Make final adjustments to blade support arms and guide assemblies.
Adjust to
assure the blade travels smoothly. Blade should rest on rear guide, but should not touch
the bottom of either side guide assembly.
3. Adjust the setting contact point.
Position the blade so the gauge foot is in between two
teeth. Use the hex key to bring the setting contact point towards the gauge foot until the
dial indicator reads 15-20 thousandths.
FIG. 3-2
SM0299B
Blade Rest
Bolt
Blade Rest
Bolt