Maintenance
Drive Bearing
3
3-12
3087doc041610
Maintenance
3.12 Drive Bearing
LT30 Revisions C1+
LT40 Revisions C2+
Refill the fluid in the drive-side cylinder bearing housing every 1000 hours of operation.
Remove the top and bottom oil plugs. Pour an Automatic Transmission Fluid (ATF) such
as Dexron III ATF into the top hole until it begins to flow from the bottom hole. Reinstall
the square oil plug to the bottom hole and the vented oil plug to the top hole.
See Figure 3-8.
NOTE:
The cylinder bearing drive system may be retrofitted to sawmills built prior to
Revs. C1 & C2.
FIG. 3-8
1000