Installation
5. Secure the boot to the intake auger tube with the
clamps provided. Apply the bottom boot to the end of
the intake auger tube and secure it with the clamp.
Tighten the clamp on the boot to secure it to the side
hopper. Apply a bead of silicon between on the auger
tube next to the inlet pipe and furnace panel to seal
out water and snow.
On Board Air Cleaner Installation
The Renovator Pellet Burner has the capability to clean the fire pot with compressed air supplied by an on
board air compressor. This allows for easier ignition as well as lower maintenance. Below is a brief explanation
of the installation process.
NOTE: Disconnect all power during installation.
1. Disconnect the wiring and remove the plastic cover
of the burner.
Note: The burner does not need to be
removed from the furnace/boiler to perform this
installation, the burner is shown off the furnace for
reference only. The location of the air line connector
is below the combustion fan on the left side. Connect
the supplied air hose to the air line connector on the
burner.
6. Raise the leg supports to a point just below the
intake auger tube. Tighten the “u” bolts on the leg sup
-
ports to secure the legs to the leg supports. Fill the side
hopper with wood pellets and prime the auger follow
-
ing the directions on page 20.