Bleeding The System
While filling the boiler, close the cold water return valve on the furnace for two or three minutes, and then
open the valve. This will force trapped air out of the hot water supply line. Repeat this process with the hot
water supply valve on the furnace to force air out of the cold water return line. Once both lines have been
“bled” continue filling the furnace until the system is full and water comes out of the vent pipe.
Note: Air in the water lines can cause damage to the pump.
Installation
Renovator Pellet Burner Installation
The burner come pre installed in its mounting location on the furnace.
The water temp probe must be installed in the well on the
supply line of the furnace.
Install the probe in the well on the supply line. Make sure
the probe set screw contacts the metal of the probe. DO NOT
clamp the probe by the wire, this will damage the probe.
Contact paste can be used to increase the accuracy of the
probe.
Connect the wires to the burner. The Renovator
Pellet Burners have very simple connections that
allow for easier removal for cleaning and mainte
-
nance.
A. Power Switch
B. Fuse (Replacement P/N: 011-0009)
C. Power Lead In
D. To Feed Auger
E. To Temperature Sensor
Not shown here: Draft controller connections and
the air compressor connections.
The protective cover on the burner cannot be re
-
moved without disconnecting these cables.