23
Force 30 Owners Manual
2015
3.
In phase two, the soft start level, the auger feeds the
burner 5 times with three second operation intervals on the
auger before it goes over completely to full burn mode. The
three values in this menu can be changed.
4.
The next menu shows the burn mode the burner. The
power displayed is the approximate input power. This is
where the settings for the burner are changed when adjust
-
ing the furnace with a flue gas analyzer. This is made by
adjusting the time for the feeding of the auger and time be
-
tween the feeds. You can also select the mode in this menu.
The choices are LOW and HIGH, where the user determines
the feed rate, and AUTO mode, where the PLC determines
the feed rate. See step 5 for adjusting AUTO mode. Press
buttons 2 and 3 together to change this value. You do not
have to press button 4 and the white button prior to chang
-
ing this setting.
5.
The Startdos value in this menu (this is a different setting
than the startdos previously described) is adjustable be
-
tween 100 and 400 grams and is the adjustment used when
the burner is in Auto burning mode. The MAX RUNTIME
value is how long the burner will run before shutting down
to self clean. The default value shown is 1/2 an hour. If heat
is still called for, the burner will restart after the cleaning
is completed. You can also read the operation time of the
burner and how many times it has started.
BURNING MODE LOW
POWER kW 15.0
ON +09.5
OFF
+10.0
Menu/Ok
1
2
3
4
SOFT START
SCREW ON +03.5
SCREW OFF +15.0
NO OF 05.0
Menu/Ok
1
2
3
4
Menu/Ok
STARTDOS +125 g
MAX 0.5
RUNTIME +00000
No OF 00000
1
2
3
4
Operation
6.
This menu displays the current room temperature and
allows you to set the desired temperature. The selected tem-
perature can be changed. The room temp is the temperature
that the supplied temp sensor is detecting.
The burner comes with a temperature sensor that starts
and stops the burner. A wall mounted thermostat can be
wired directly to the PLC on the burner. If a wall mounted
thermostat is used, disconnect the temperature sensor. If a
wall mounted thermostat is used, the selected value can no
longer be changed in this menu, and is instead controlled by
the thermostat.
Menu/Ok
OPERATE TEMP
ROOM TEMP +69
SELECTED +72
1