background image

24

Airflow input

Airflow output

Abluft

Zuluft

5 mm

16 mm
17 mm
23 mm
28 mm
34 mm
38 mm
64 mm

120 mm
122 mm
172 mm
176 mm
180 mm
185 mm
210 mm
408 mm
450 mm
565 mm
598 mm
650 mm
690 mm
770 mm

0,2“
0,6“
0,7“
0,9“
1,1“
1,3“
1,5“
2,5“
4,7“
4,8“
6,8“
6,9“
7,1“
7,3“
8,3“

16,1“
17,7“
22,2“
23,5“
25,6“
27,2“
30,3“

From mm to inch:

All measurements in mm
(for inch see list beside)

DIMENSIONS

 

(all Visualizers)

ABMESSUNGEN

 

(alle Visualizer)

Содержание VZ-15b

Страница 1: ...INSTRUCTIONS VZ 15b VZ 35b VZ 45b ENGLISH R...

Страница 2: ...ROR ARM 1 DURING TRANSPORTATION PROTECT THE UNIT FROM EXCESSIVE SHOCKS Avoid installing the Visualizer in environments where there are radiations Avoid installing the Visualizer in locations exposed t...

Страница 3: ...age 11 Page 11 Page 12 Page 12 Page 12 Page 12 Page 13 Page 13 Page 13 Page 14 Page 14 Page 14 IMPORTANT Page 15 IMPORTANT Page 15 IMPORTANT Page 15 Page 15 Page 15 Page 16 Page 16 18 Page 18 19 Page...

Страница 4: ...chaper applies to all 3 Visualizer models or just to one or two of these models Therefore it is important that you check which Visualizer model you have 12 Control panel of the camera 15 ZOOM tele 16...

Страница 5: ...ed for image processing as it is the original unprocessed signal On the VZ 35b this output can be switched to YUV see below VZ 35b VZ 15b On the VZ 15b the RGBS signal is actually only a converted Y C...

Страница 6: ...er industry so there should be no problems with the most multiscan monitors or projectors However if your display device does not support separate sync inputs but has only one sync input normally mark...

Страница 7: ...elease button 2 Pull arm upwards BASIC PREPARATIONS all Visualizers 1 Press the release for the arm 11 and simultaneously pull the arm upward Make sure that the arm is extended to its full length 2 Co...

Страница 8: ...ven from a great distance to the unit If you want to record people you should turn off the light with the LIGHT off key 23 so that they are not dazzled WORKING ON THE WORKING SURFACE all Visualizers L...

Страница 9: ...e working with an optional lightbox the light of the Visualizer has to be switched off WORKING WITH TRANSPARENCIES all Visualizers REFLECTIONS GLARE all Visualizers IMPORTANT Reflections can appear on...

Страница 10: ...on Preset When using the POWER ON key 28 the unit is running the Power on Preset Zoom and Focus on an A5 format on the working surface The power on preset can also be recalled when the unit is in oper...

Страница 11: ...osition the picture of the Visualizer is shown The signal is looped through the video recorder CONNECTING A NUMBER OF MONITORS out in in in in out out out In this way a number of monitors can be conne...

Страница 12: ...ly The lighting and focus problems are eliminated by the Visualizers superb light and scan system Just connect one of the outputs of the Visualizer to the corresponding input of the video printer Conn...

Страница 13: ...heir infrared remote controls he has the possibility of changing the frequency on one of the units For switching one Visualizer and its remote control to the second frequency just use the red switch b...

Страница 14: ...tical cleaner only CAUTION Sensitive front coated mirror Move the tissue in vertical direction only Horizontal scratches would cause ugly reflections Avoid high pressure The glass covering the mirror...

Страница 15: ...the colors are darker than usual By pressing the FREEZE key on the camera control panel 12 of the VZ 45b the current image is stored and remains on the projection screen or monitor Pressing the FREEZE...

Страница 16: ...By simultaneously pressing the SAVE and POWER ON key the camera menu can be reset to the factory setup This function is important if inexperienced users have made wrong adjustments in the menu It is a...

Страница 17: ...tions 2 Used when shooting a dark object and a highly illuminated object at the same time Do not use positive detail settings for text The recommended setting is 17 G SYNC In the ON position a sync si...

Страница 18: ...TA DOWN keys For adjustment of the SC phase color phase press the FUNCTION UP or FUNCTION DOWN key until SC and 0 180 appears on the monitor Start with the rough adjustment of 0 180 followed by fine a...

Страница 19: ...e noise In the long exposure mode you can adjust the shutter speed in frames 1 50 second 2 General Setup menu of VZ 45b 3 System Setup menu of VZ 45b C TEMP COLOR TEMPERATURE WHT BAL WHITE BALANCE Sel...

Страница 20: ...NC connectors RGB 0 7 Vpp 75W Sync 2 Vpp switchable with IMAGE keys converted Y C signal 4 x BNC connectors RGB 0 7 Vpp 75W Sync 2 Vpp switchable with IMAGE keys Y C S VHS output 7 pin connector Y sig...

Страница 21: ...to change 12 V DC output for lightbox can be switched on and off with the light keys 1 5A 90 120 V or 210 264 V AC 50 60 Hz SERIAL PORT 9 pin D Sub Function ASCII value Image on Iris open Focus plus Z...

Страница 22: ...lity is good on the monitor check the adjustment of the projector Autoiris does not work The autoiris function is switched off when using the IRIS keys 19 20 It is switched on again when using the ZOO...

Страница 23: ...check the blanking of the projector If you are sure that the lightfield is still much larger than the recorded area and it is not due to a wrong adjustment of your monitor or your projector consult yo...

Страница 24: ...2 mm 172 mm 176 mm 180 mm 185 mm 210 mm 408 mm 450 mm 565 mm 598 mm 650 mm 690 mm 770 mm 0 2 0 6 0 7 0 9 1 1 1 3 1 5 2 5 4 7 4 8 6 8 6 9 7 1 7 3 8 3 16 1 17 7 22 2 23 5 25 6 27 2 30 3 From mm to inch...

Страница 25: ...data down text data down text Storing presets Sync on green switching Unlocking the camera menu VZ 35b RGBS YUV switching VZ 45b Sync switching C or VD HD Resetting the camera menu Recalling power on...

Отзывы: