background image

SPECIFICATIONS

Pick-up element / video

                           VZ-45b 

Built-in camera system

3 CCD unit - 1/2" interline transfer 

Effective pixels:

Signal format:

782 (H) x 582 (V)  x  3

Non-interlaced, 1/50

Resolution:

Frequency:

horizontal: 800 lines, vertical: 575 lines

Horizontal: 31.25 kHz, Vertical: 50 Hz

White balance:

automatic / 3200K / 5600K / manual

Iris:

automatic / manual

Optics:

8.5 x telezoom 20 - 170 mm, f = 2.0

Depth of focus:

tele position: 70mm (2.75"), wide position: 250mm (9.7")

Gain control:

automatic / manual 0 to 18 dB switchable

Electronic shutter:

off / step / manual

Operation

Infrared remote control:

functions: zoom, focus, iris, image on/off, preset 1+2

Control panel:

functions: zoom, focus, iris, image on/off, light, power, preset 1+2 

zoom on A5, focus on working surface level, light on, iris auto

Power-on preset:

2 programmable presets:

programmable settings: zoom, focus, iris, light, image

Camera control panel:

functions: menu, display, functions up/down, 
data up/down, white/black  balance, bars, 
(Reset function)

Lighting element

telezoom, electronically synchronized with camera lens

Light source:

Light/image synchronization:

24 V / 150 W halogen-lamp, 3200 kelvin (with constant spectrum !)

Spare lamp:

built-in lamp changer with LED indicator

Scanning area

objects on working surface:

width: 36-270mm, length: 42-360mm, height: up to 250mm

objects in a room:

to eternity

Connections

RGBS (Data) output:

Preview (Data) output:

15 Pin S-VGA connector plus 5 x BNC, 
 (RGB: 0.7 Vpp 75

W, 

Sync: 2 Vpp) 

switchable with Image-keys

15 Pin S-VGA connector (RGB: 0.7 Vpp 75

W, 

Sync: 2 Vpp)

Constant signal output - even when image is switched off

No video outputs (DATA-RGBS only)

Video outputs (Composite, Y/C
Video RGBS or Component YUV):

Parallel port:

input for external wired remote control

Serial port:

configuration: RS 232, extended protocol including status report

General specifications

Power source:

Power consumption:

230 W

Working surface:

reversible: one side crystalline white / one side dark grey

Weight:

Made in:

16 kg (34 lbs)

European Community (Austria)

These specifications can only be 
found on WolfVision Visualizers !

Specifications and availability subject to change.

12 V DC output:

for lightbox (can be switched on and off with the "light"-keys), 1.5A

90-120 V or 210-264 V AC,  50/60 Hz

SERIAL PORT

(9-pin D-Sub):

Function:     ASCII-value:

Image on
Iris open
Focus plus
Zoom wide
Image off
Iris close
Focus minus
Zoom near
Power on
Power off
Preset 1
Preset 2
Light on
Light off
Menu (first use 218!)
Display / BARS
Function up
Function down
Data up / white
Data down / black
Save Preset 1
Save Preset 2
Unlock menu
Switch IR-mode A/B
Preset max. wide
Preset A4
Preset A5
Preset A6
Preset A7
Preset A8
Preset max. tele

192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
216
217
218
221
229
230
231
232
233
234
235

Detailled description of serial protocol 
(including status report and position
setting) available on request from your 
WolfVision dealer.

Please note that ASCII-values must 
be sent as one byte (e.g. 199 and 
not 1 + 1 + 9)

("ASCII"-values are sometimes
 also called "HEX"-codes or
 "Decimal"-codes)

*   Parallel GND is the ground for the opto-isolated control inputs. DC GND is the ground
     for DC + 12 V and also for Video out. If you want to use DC + 12 V for the control
     inputs make a connection between DC GND and Parallel GND.
**  Please note that there is no 12 V power supply when the Visualizer is in the standby 
     mode. For switching on the unit through the Parallel port use an external power supply
*** VZ-35b and VZ-15b only.

1   2   3    4    5   6    7   8    9   10  11  12 13

14   15  16 17  18 19 20  21  22 23  24  25

Parallel port: 

(25-pin D-Sub, 12-24 V)

Serial port: 

(9-pin D-Sub)

1.  Image on
2.  Iris open
3.  Focus plus
4.  Zoom far
5.  Power on
6.  Preset 1
7.  Light on
8.  Video out ***
9.  Menu

10.  Function up
11.  Data up/White
12.  Save
13.  Parallel GND*
14.  Image off
15.  Iris close
16.  Focus minus
17.  Zoom near
18.  Power off

19.  Preset 2
20.  Light off
21.  DC GND / Video GND*
22.  Display / Bars
23.  Function  down
24.  Data down / Text
25.  DC + 12 V**

(male - front side)

Pins:             2:RX,  3:TX,  5:GND,  7:RTS,  8:CTS
Baud rate:    19200*, databits: 8, stopbit: 1, parity: no
Between sending codes there should be a break of at least 250ms !
(Except ZOOM, FOCUS and IRIS as the code is constantly sent as long
as these function are activated)
* It is possible to switch to 9600 baud - please contact your WolfVision dealer!

9-pin D-Sub connector 
on unit, male, front side

5

9

2

7

3 4

8

1

6

CONTROL CONNECTORS 

(all Visualizers)

21

Содержание VZ-15b

Страница 1: ...INSTRUCTIONS VZ 15b VZ 35b VZ 45b ENGLISH R...

Страница 2: ...ROR ARM 1 DURING TRANSPORTATION PROTECT THE UNIT FROM EXCESSIVE SHOCKS Avoid installing the Visualizer in environments where there are radiations Avoid installing the Visualizer in locations exposed t...

Страница 3: ...age 11 Page 11 Page 12 Page 12 Page 12 Page 12 Page 13 Page 13 Page 13 Page 14 Page 14 Page 14 IMPORTANT Page 15 IMPORTANT Page 15 IMPORTANT Page 15 Page 15 Page 15 Page 16 Page 16 18 Page 18 19 Page...

Страница 4: ...chaper applies to all 3 Visualizer models or just to one or two of these models Therefore it is important that you check which Visualizer model you have 12 Control panel of the camera 15 ZOOM tele 16...

Страница 5: ...ed for image processing as it is the original unprocessed signal On the VZ 35b this output can be switched to YUV see below VZ 35b VZ 15b On the VZ 15b the RGBS signal is actually only a converted Y C...

Страница 6: ...er industry so there should be no problems with the most multiscan monitors or projectors However if your display device does not support separate sync inputs but has only one sync input normally mark...

Страница 7: ...elease button 2 Pull arm upwards BASIC PREPARATIONS all Visualizers 1 Press the release for the arm 11 and simultaneously pull the arm upward Make sure that the arm is extended to its full length 2 Co...

Страница 8: ...ven from a great distance to the unit If you want to record people you should turn off the light with the LIGHT off key 23 so that they are not dazzled WORKING ON THE WORKING SURFACE all Visualizers L...

Страница 9: ...e working with an optional lightbox the light of the Visualizer has to be switched off WORKING WITH TRANSPARENCIES all Visualizers REFLECTIONS GLARE all Visualizers IMPORTANT Reflections can appear on...

Страница 10: ...on Preset When using the POWER ON key 28 the unit is running the Power on Preset Zoom and Focus on an A5 format on the working surface The power on preset can also be recalled when the unit is in oper...

Страница 11: ...osition the picture of the Visualizer is shown The signal is looped through the video recorder CONNECTING A NUMBER OF MONITORS out in in in in out out out In this way a number of monitors can be conne...

Страница 12: ...ly The lighting and focus problems are eliminated by the Visualizers superb light and scan system Just connect one of the outputs of the Visualizer to the corresponding input of the video printer Conn...

Страница 13: ...heir infrared remote controls he has the possibility of changing the frequency on one of the units For switching one Visualizer and its remote control to the second frequency just use the red switch b...

Страница 14: ...tical cleaner only CAUTION Sensitive front coated mirror Move the tissue in vertical direction only Horizontal scratches would cause ugly reflections Avoid high pressure The glass covering the mirror...

Страница 15: ...the colors are darker than usual By pressing the FREEZE key on the camera control panel 12 of the VZ 45b the current image is stored and remains on the projection screen or monitor Pressing the FREEZE...

Страница 16: ...By simultaneously pressing the SAVE and POWER ON key the camera menu can be reset to the factory setup This function is important if inexperienced users have made wrong adjustments in the menu It is a...

Страница 17: ...tions 2 Used when shooting a dark object and a highly illuminated object at the same time Do not use positive detail settings for text The recommended setting is 17 G SYNC In the ON position a sync si...

Страница 18: ...TA DOWN keys For adjustment of the SC phase color phase press the FUNCTION UP or FUNCTION DOWN key until SC and 0 180 appears on the monitor Start with the rough adjustment of 0 180 followed by fine a...

Страница 19: ...e noise In the long exposure mode you can adjust the shutter speed in frames 1 50 second 2 General Setup menu of VZ 45b 3 System Setup menu of VZ 45b C TEMP COLOR TEMPERATURE WHT BAL WHITE BALANCE Sel...

Страница 20: ...NC connectors RGB 0 7 Vpp 75W Sync 2 Vpp switchable with IMAGE keys converted Y C signal 4 x BNC connectors RGB 0 7 Vpp 75W Sync 2 Vpp switchable with IMAGE keys Y C S VHS output 7 pin connector Y sig...

Страница 21: ...to change 12 V DC output for lightbox can be switched on and off with the light keys 1 5A 90 120 V or 210 264 V AC 50 60 Hz SERIAL PORT 9 pin D Sub Function ASCII value Image on Iris open Focus plus Z...

Страница 22: ...lity is good on the monitor check the adjustment of the projector Autoiris does not work The autoiris function is switched off when using the IRIS keys 19 20 It is switched on again when using the ZOO...

Страница 23: ...check the blanking of the projector If you are sure that the lightfield is still much larger than the recorded area and it is not due to a wrong adjustment of your monitor or your projector consult yo...

Страница 24: ...2 mm 172 mm 176 mm 180 mm 185 mm 210 mm 408 mm 450 mm 565 mm 598 mm 650 mm 690 mm 770 mm 0 2 0 6 0 7 0 9 1 1 1 3 1 5 2 5 4 7 4 8 6 8 6 9 7 1 7 3 8 3 16 1 17 7 22 2 23 5 25 6 27 2 30 3 From mm to inch...

Страница 25: ...data down text data down text Storing presets Sync on green switching Unlocking the camera menu VZ 35b RGBS YUV switching VZ 45b Sync switching C or VD HD Resetting the camera menu Recalling power on...

Отзывы: