Sub-Zero, Sub-Zero & Design, Sub-Zero & Snowflake Design, Dual Refrigeration, The Living Kitchen, Great American Kitchens The Fine Art of Kitchen Design, Wolf, Wolf & Design, Wolf Gourmet, W & Design, red colored knobs, Cove, and Cove & Design, are registered trademarks and service marks of Sub-Zero Group, Inc. and its subsidiaries.
All other trademarks are property of their respective owners in the United States and other countries.
TROUBLESHOOTING
INSTALLATION
Complete the Installation
FILTERS
Install grease cups at the bottom rear edge of the hood.
Orient filters with lines running vertically. To install, place the
top edge of the filter against the spring, press upward then
rotate the bottom toward the back of the hood. Refer to the
illustration below.
LIGHT BULBS
A suction-cup-style light bulb changer is provided with
the ventilation hood. To install, use the changer to push
the bulb into the receptacle and rotate counterclockwise
one-quarter turn. Refer to the illustration below.
If equipped, install heat lamp bulbs (not included). Use E27,
R125 (250W maximum) bulbs, available at hardware stores
or through an authorized Wolf dealer.
WOLF LOGO
To attach the Wolf logo, clean the mounting area with rub-
bing alcohol. Remove the paper backing, position the logo
parallel with the bottom of the hood, then press into place.
FILTER
SIDE VIEW
SPRING
GREASE
CUP
LIGHT BULB
CHANGER
Filter installation.
Light bulb installation.
Troubleshooting
IMPORTANT NOTE:
If the ventilation hood does not operate
properly, follow these troubleshooting steps:
•
Verify electrical power is supplied to the ventilation hood.
•
Verify proper wiring connections.
•
If the ventilation hood does not operate properly, contact
Wolf factory certified service. Do not attempt to repair
the hood. Wolf is not responsible for service required to
correct a faulty installation.
Blower Assemblies
CAUTION
To reduce the risk of fire and electric shock, install this
ventilation hood with a blower manufactured by Wolf.
IMPORTANT NOTE:
Refer to installation instructions pro-
vided with each blower assembly for specific mounting and
wiring instructions.
INTERNAL BLOWER
Internal blowers are mounted inside the hood at the time of
installation.
REMOTE BLOWER
Remote blowers can be mounted on the roof or exterior
wall. Locate the blower so the length of the duct run and
number of elbows and transitions are kept to a minimum.
If the duct run exceeds 15 m, a higher CMH blower may be
required to maintain proper air flow. Refer to the illustrations
below for dimensions of Wolf remote blowers.
622
mm
394
mm
718
mm
527
mm
629
mm
356
mm
121
mm
254 mm
DIAMETER
375
mm
749
mm
749
mm
457 mm
559
mm
257
mm
184
mm
254
mm
254 mm
DIAMETER
375
mm
749
mm
749
mm
533 mm
635
mm
264
mm
184
mm
254
mm
254 mm
DIAMETER
1014 | 1528 CMH remote blower.
2028 CMH remote blower.
2535 CMH remote blower.
BLOWER SPECIFICATIONS