background image

Installation instructions and

how to use and look after your

built-in cooker hoods 

NEFF (UK) Ltd

Содержание D72F58N0GB

Страница 1: ...Installation instructions and how to use and look after your built in cooker hoods NEFF UK Ltd...

Страница 2: ...Abb 1 ELECTRO Fig 1 GAZ min 650 min 550 2...

Страница 3: ...installation 7 Operating modes 8 Exhaust air mode 8 Circulating air mode 8 Operation 9 Cleaning and Care 10 Removing and installing the grease filters 11 Removing and installing the metal mesh grease...

Страница 4: ...rials can be reclaimed by recycling old appliances This appliance is identified according to the European Directive 2002 96 EC on waste electrical and electronic equipment WEEE The directive specifies...

Страница 5: ...stomer service or a similarly qualified person to prevent hazardous situations Only a qualified technician may install including electrical connection service or repair the extractor hood Always isola...

Страница 6: ...bs observe the appropriate national statutory regulations e g in Germany Technische Regeln Gasinstallation TRGI Observe the currently valid installation regulations and instructions of the gas applian...

Страница 7: ...if you are cooking food with oils or fats e g chips Overheated oils or fats can easily ignite A risk of fire can be prevented by cleaning the grease filters regularly and changing the activated carbo...

Страница 8: ...ust be connected and switched off Simultaneously press buttons and r until is displayed Repeatedly press buttons and r to switch the electronic control back to exhaust air mode by display The extracto...

Страница 9: ...f by hand the fan automatically switches back to setting 2 after 10 minutes Fan run on Press button r The fan runs for 10 minutes at the selected setting The r symbol is lit on the display Then the fa...

Страница 10: ...ase particles from the kitchen fumes The filter mats consist of fire proof metal RISK OF FIRE As the filters become more saturated with greasy residue the flammability increases The function of the ex...

Страница 11: ...be replaced approximately 2x year The activated carbon filter is available from specialist outlets customer service or the Online Shop see Optional accessories Use original filters only Activated carb...

Страница 12: ...ch the glass tube Therefore use a clean cloth when inserting the bulb 3 Close the inner frame of the halogen bulb NOTE The inner frame of the halogen bulb will not close unless it was fully opened bef...

Страница 13: ...ong rough exhaust air pipes a lot of pipe bends or pipe diameters less than 150 mm are used the air capacity will be less than optimum and there will be an increase in noise Use only pipes or hoses ma...

Страница 14: ...equired connection data can be found on the rating plate inside the appliance when the grease filters have been removed Length of the power cord approx 1 30 m This extractor hood complies with the EC...

Страница 15: ...bearing capacity Ensure that the depth of the drilled holes corresponds with the length of the screws Ensure that the wall plugs are secure Max weight in kg 40 Design subject to modification in line w...

Страница 16: ...Mark the holes for the safety screws Detach the extractor hood drill holes for the safety screws and press in wall plugs flush with the wall 2 Attach the extractor hood and screw in the safety screws...

Страница 17: ...earing protective gloves during installation 1 Separate the flue ducts To do this remove the adhesive tape 2 Remove the protective film from both flue ducts 3 Insert one flue duct into the other NOTE...

Страница 18: ...18 Notes...

Страница 19: ...19 Notes...

Страница 20: ...20 Notes...

Страница 21: ...21 Notes...

Страница 22: ...22 Notes...

Страница 23: ...23 Optional accessory Z5131X5 Z5132X5 Z5133X5 669419 236 669659 321 669648 281...

Страница 24: ...9000 355385 Printed in Germany 1108 Es NEFF UK Ltd Grand Union House Old Wolverton Road Old Wolverton Milton Keynes MK12 5PT Tel 01908 328300 Fax 01908 328399...

Отзывы: