4
|
English
SPECIFICATIONS
Installation Requirements
Pro ventilation hoods are recommended for use with all
Wolf cooking appliances. Installation of the hood should
be 762 mm to 914 mm from the bottom of the hood to the
countertop.
Pro wall hoods require an internal, in-line or remote blower
assembly, avail able through an authorized Wolf dealer.
Refer to specific installation instructions provided with each
blower assembly. Additional information can also be found
on our website, wolfappliance.com.
Optional stainless steel duct covers and backsplashes are
available through an authorized Wolf dealer. If a duct cover
or backsplash will be used, it must be attached prior to
installation of the hood. Installation instructions are provided
with each accessory.
Electrical
Installation must comply with all applicable electrical codes
and be properly grounded (earthed).
Locate the electrical supply as shown in the illustration
below. A separate circuit, servicing only this appliance is
required.
ELECTRICAL REQUIREMENTS
Electrical Supply
220-240 V AC, 50/60 Hz
Service
15 amp dedicated circuit
E
152
mm
127
mm
762
mm
TO
914
mm
BOTTOM EDGE TO COUNTERTOP
Electrical location.
Rating plate location.
RATING PLATE
AIR RECIRCULATION INSTALLATION
Pro wall hoods (76 cm and 91 cm widths) with an internal
blower (1014 CMH or less), can be used in a non-ducted
application with a recirculating filter. In this installation,
kitchen air is passed through a filter and returned to the
room. A recirculation kit, available through an authorized
Wolf dealer is required.
IMPORTANT NOTE:
Connection of this appliance should be
through a fused connection unit or a suitable isolator, which
complies with national and local safety regulations. The
on/off switch should be easily accessible after the appli-
ance has been installed. If the switch is not accessible after
installation (depending on country) an additional means of
disconnection must be provided for all poles of the power
supply. When switched off there must be an all pole contact
gap of 3 mm in the isolator switch. This 3 mm contact dis-
connect gap must apply to any isolator switch, fuses and/or
relays according to EN60335.
Electrical
Shock
Hazard
Plug power cord directly into a properly
grounded (earthed) outlet.
Do not defeat the grounding (earthing)
nature of the plug.
Do not use adapter or extension cord.
Failure to follow these instructions could
cause serious injury or death.
See installation instructions