Wolf Integrated Modules
47
wolfappliance.com/specs
Planning Information
When multiple cooktops or modules are installed side by
side, the dimensions provided in the chart are derived by
adding 1
1
/
4
" (32) additional space for each additional unit,
to give you the total countertop cut-out width. Dimensions
include the optional filler strip available through your
authorized Wolf dealer. For local dealer information,
visit the find a showroom section of our website,
wolfappliance.com.
Refer to specifications on the following pages for specific
installation requirements and limitations for each integrated
module. Review specific installation instructions for
product-to-product capabilities. Installation specifications
for induction and electric cooktops can be found on page
34 and for the gas cooktop on page 42.
IMPORTANT NOTE:
Wolf does not recommend the use of
downdraft ventilation with the grill, steamer or fryer
modules.
ELECTRICAL REQUIREMENTS
Wolf electric modules have a 4' (1.2 m) conduit and require
a separate, grounded 3-wire 240/208 V AC, 60 Hz, 15 amp
service (20 amp for electric grill) with its own circuit
breaker. Gas modules require a separate, grounded 120 V
AC, 60 Hz, 15 amp service with its own circuit breaker and
grounded 3-prong receptacle located within reach of the
6' (1.8 m) power cord.
When multiple cooktops or modules are installed side by
side, each unit must have its own separate electrical
supply.
GAS REQUIREMENTS
A gas supply line of
3
/
4
" rigid pipe must be provided to the
gas module. If local codes permit, a certified, 3' (.9 m) long,
1
/
2
" or
3
/
4
" ID flexible metal appliance connector is recom-
mended to connect the module to the gas supply line.
When multiple gas cooktops or modules are installed next
to one another, they can receive their gas supply from a
common line. However, each unit must have its own regu-
lator installed between the mainline and the cooktop or
module.
Wolf gas modules are designed to operate on natural gas
at 5" (12.5 mb) WC pressure or LP gas at 10" (25 mb) WC
pressure. The minimum line pressure is 7" (17.5 mb) WC
for natural gas and 11" (27.4 mb) WC for LP gas. The
maximum gas supply pressure to the regulator should
never exceed 14" (34.9 mb) WC, .5 psi (3.5 kPa).
Wolf natural gas cooktops will function up to an altitude
of 10,250' (3124 m) without any adjustment. LP gas
cooktops will function up to 8,600' (2621 m) without
adjustment. If the installation exceeds these elevations,
contact your authorized Wolf dealer for a high altitude
conversion kit.
Multiple Cooktops
COUNTERTOP CUT-OUT
WIDTH
2 Modules
29
1
/
4
"
(743)
3 Modules
44
1
/
2
"
(1130)
4 Modules
59
3
/
4
"
(1518)
30"
(762)
Cooktop / Module
44
1
/
4
"
(1124)
30"
(762)
Cooktop / 2 Modules
59
1
/
2
"
(1511)
36"
(914)
Cooktop / Module
50
1
/
4
"
(1276)
2
1
/
2
"
(64) min
19
1
/
4
"
(489)
CUT-OUT
DEPTH
CUT-OUT WIDTH
14"
(356)
MODULE
CUT-OUT
WIDTH
FRONT OF COUNTERTOP
Countertop cut-out.