9 Siting instructions
Transport
Boiler/stratification cylinder
- The boiler and the stratification cylinder are transported, fully packaged, on a pallet
- A sack truck is a suitable means of transportation
- Position the sack truck behind the boiler or stratification cylinder, secure with a strap
and transport to the installation location
- Remove strap and packaging
- Remove the two fixing screws on the pallet
- Lift the boiler and/or stratification cylinder off the pallet
The COB and TS are installed adjacent to the wall, which means that a clearance of
70 cm only needs to be observed at the front. When installing the boiler, you should
observe the recommended wall clearances in order to simplify installation, maintenance
and servicing. The COB-40 requires a minimum room height of 1.90 m.
The minimum clearance via COB-15/20/29 is 30 cm, for the COB-40 this is 40 cm.
Recommended minimum
wall clearances
COB with
TS (right
or left)
COB-40
minimum
room height
COB
COB with
CS behind
70 cm
70 cm
70 cm
70 cm
70 cm
70 cm
190 cm
Installation information
Adjustable feet
- A level and load-bearing base is required for the installation of the
boiler or the stratification cylinder, to prevent air collection in the
boiler and therefore system faults.
- Level the boiler and stratification cylinder horizontally using
adjustable feet.
- Open flue oil condensing boilers must only be installed in a room
which complies with the appropriate ventilation requirements.
Otherwise there is a risk of asphyxiation or poisoning from the
escaping flue gas, caused by operation with a leaking flue gas system.
- The boiler may only be installed in a frost-free room to prevent the
frost damaging the installation. Drain the boiler, stratification cylinder
and heating system if there is a risk of frost when the system has
been shut down.
- The boiler may not be installed in a room with corrosive vapours
or in very dusty conditions (workshops, washrooms, hobby rooms
etc.), since this may lead to damage to the components and/or heavy
contamination of the heat exchanger.
- The combustion air must be free from halogenated hydrocarbons.
Halogenated hydrocarbons lead to premature aging of the heat
exchanger, due to corrosion.
With the COB, a surface temperature of 40°C is not exceeded during proper use. For
installation in oil storage rooms, the respective state fire regulation must be adhered to.
Note
Note
Note