Cooktop Installation
14
Multiple Cooktop Installation
IMPORTANT NOTE:
Unframed induction and electric
cooktops are not designed to be installed in combination
with other cooktops.
If the framed induction or electric cooktop is to be used
with any combination of additional cooktops or modules
with a filler strip, the dimensions provided in the chart
below are derived by adding 1
1
/
4
"
(32)
additional space for
each additional unit, to give you the total countertop cut-
out width. Dimensions include the filler strip.
IMPORTANT NOTE:
For models CT15I/S and CT15E/S, the
cut-out width should be increased from 13
3
/
8
"
(340)
to 14"
(356)
when installed with multiple cooktops.
When multiple cooktops are installed side by side, each
unit must have its own separate recommended electrical
circuit.
When two or more modules are installed together, an
integrated module filler strip is recommended. If a 30"
(762)
downdraft ventilation system is also installed, an inte-
grated module support for downdraft ventilation is also
required.
The filler strip and other accessories are available through
your authorized Wolf dealer. For local dealer information,
visit the find a showroom section of our website,
wolfappliance.com.
Multiple Cooktops
COUNTERTOP CUT-OUT
WIDTH
2 Modules
29
1
/
4
"
(743)
3 Modules
44
1
/
2
"
(1130)
4 Modules
59
3
/
4
"
(1518)
30"
(762)
Cooktop / Module
44
1
/
4
"
(1124)
30"
(762)
Cooktop / 2 Modules
59
1
/
2
"
(1511)
36"
(914)
Cooktop / Module
50
1
/
4
"
(1276)
Unframed Installations
Unframed induction and electric cooktops can be
mounted flush with the top of the countertop or as a
frameless installation with the glass-ceramic top mounted
on top of the countertop surface. In either installation the
countertop cut-out dimensions are the same. If the
cooktop is to be mounted flush with the countertop, a
recessed area surrounding the countertop cut-out must
be provided. Refer to the installation illustrations on
pages 12–13.
IMPORTANT NOTE:
An installation kit and additional
instructions required for a flush mount installation
are provided with the unframed cooktop. The template
provided with the unframed cooktop is for reference only.
Use the actual cooktop for marking the cut-out.
Flush mount installations are intended for granite, solid
surface or stone countertop surfaces only. Contact
with hot cookware may cause damage to countertop
surfaces that are not resistant to high heat.