7.

 

Ethernet

:

 

The 10/100M Ethernet connector is used to connect with a 

computer to modify the display settings remotely. CAT5 network cables are 
recommended for medium distances. CAT6 twisted pair shielded cables are 
recommended for longer distances.  

8.

 

RS-485 In/Out

:

 

These RJ-45 jacks are used for dynamic Tally/IMD controls. 

Two jacks are provided for in & out daisy chain arrangements. They are 
wired identically. Refer to Figure 2-5 below for the pinout and Table 2-2 for 
terminal connections. These connections are also used for system software 
upgrades. Either CAT5 or CAT6 cables may be used for these jacks. 

9.

 

Tally

:

 

This RJ45 jack controls the tally lights on the front panel. Refer to 

Figure 2-5 below for the pinout and Table 2-1 for the terminal connections. 
Either CAT5 or CAT6 cables may be used for these jacks. 

Rear Panel Connectors 

The following figure and tables detail the connections of the Tally and RS-485 
connectors on the rear panel. The tables are also silkscreened on the rear panel of 
the unit for your convenience. 

Table 2-1: Tally Input Connections 

 

 

 

 

Figure 2-5: Tally Input & RS-485 I/O Pin-Out 

 

 

Pin

 

Tally Terminal Name

 

CH1-Red 

CH1-Green 

CH2-Red 

CH2-Green 

5-7  NC 

GND 

Содержание RM-3270WS-3G

Страница 1: ...RM 3270WS Series RM 3270WS 3G RM 3270WS 3G2 3RU 2 Screen 7 Audio Video Monitors User Guide User Guide Part Number 821805 Revision B...

Страница 2: ...equipment and software and reviewed the documentation Wohler Technologies Inc makes no warranty or representation either express or implied with respect to software documentation their quality perfor...

Страница 3: ...nterference 7 Power 7 Compliance 7 FCC 7 ICES 003 8 CHAPTER 2 Local Operation 9 Front Panel 9 On Screen Display Features 10 Rear Panel 12 Rear Panel Connectors 14 Using the Quick Menu and the OSD Menu...

Страница 4: ...Page 4 Close Caption Page 34 Config Page 34 Color Temperature Page 35 Function Key Page 36 IMD Page 37 System Page 38...

Страница 5: ...A headphone jack allows audible stereo monitoring of the left right channels on all models Both models have stereo speakers Parameters are selected and adjusted using an On Screen Display OSD MENU An...

Страница 6: ...it is designed for a standard 19 rack Install it at ear eye level for best high frequency response and visual observation of the display screens Please adhere to the following clearances Table 1 1 Rec...

Страница 7: ...rcuitry ground is connected to the chassis Power The unit comes with a standard internal power supply and connects an AC mains power source 60W 100 to 240 VAC 10 50 60Hz through the IEC connector prov...

Страница 8: ...Page 8 their own expense ICES 003 This Class A digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe A est conforme la norme NMB 003 du Canada...

Страница 9: ...ource 3 Speakers located on rear panel Audio may be selected for monitoring through the left and right speakers Control the volume of the speakers using the Volume setting in the Quick Menu Refer to t...

Страница 10: ...utton navigates down through the menu and sub menu selections When the OSD MENU is not displayed pressing this button initiates F1 function per its function key menu setting 12 F2 Up The Up function i...

Страница 11: ...t whether to display it its aspect ratio the display brightness and the matte mode in the MARKER menu 3 Safety Marker This is used to mark a percentage area inside of the image safe for titles to be l...

Страница 12: ...ear Panel Layout SDI CVBS In 1 SDI 1 Out Ethernet Tally RS 485 In Out 12 VDC Power Connector Chassis Ground L R Audio In 1 L R Audi o Out L R Audi o In 2 SDI 1 Out L R Audio In 1 L R Audi o Out L R Au...

Страница 13: ...ource These outputs have a 500 output impedance and will produce up to a 5dBu signal 5 Left and Right Speakers The left and right speakers for the unit are located on the rear panel 6 Power Connector...

Страница 14: ...These connections are also used for system software upgrades Either CAT5 or CAT6 cables may be used for these jacks 9 Tally This RJ45 jack controls the tally lights on the front panel Refer to Figure...

Страница 15: ...a time menu which provides quick access to a few commonly used features as listed in Table 2 3 The Quick Menu appears as shown in Figure 2 7 Figure 2 7 Quick Menu Volume Setting The following is a des...

Страница 16: ...2 Use the Up and Down buttons to navigate through the submenus 3 Press the Enter button to enter the parameter selections in the chosen submenu 4 Use the Up or Down buttons to cycle through the submen...

Страница 17: ...the value of the Parameter FORMAT NO SIGNAL COLOR TEMP D65 SCAN MODE NORMAL NORMAL OVER UNDER FAST MODE OFF OFF or ON MODEL RM 3270WS 3G2 SERIAL NUMBER IP ADDRESS 192 168 1 86 COLOR VERSION Table 2 5...

Страница 18: ...arker size CENTER MARKER OFF ON or OFF Turn center marker display on or off SAFETY MARKER OFF OFF 80 85 88 90 93 95 Set safety marker size according to the aspect ratio and scan mode MARKER LEVEL 1 1...

Страница 19: ...G3 G1 G4 G2 G3 G2 G4 G3 G4 G1 G4 Select channels or SDI groups to display on the meters METER DIRECTION HORIZONTAL VERTICAL HORIZONTAL Select whether you prefer vertical or horizontal meters METER POS...

Страница 20: ...pe of waveform vector display LINE WAVE OFF ON or OFF Set whether to display the line wave LINE WAVE NUMBER 0 to Vertical Lines Set the position of the waveform display WAVE OVER LIMIT 50 50 to 100 Se...

Страница 21: ...Set lock number LANGUAGE ENGLISH ENGLISH CHINESE Set the menu language Table 2 11 Color Temp Menu Structure Color Temp Parameters Default Value Domain Range Description COLOR TEMP D65 D32 D50 D56 D65...

Страница 22: ...ption F1 SCAN SCAN NATIVE ASPECT BLUE ONLY MONO MARKER H V DELAY AUDIO METER FAST MODE TC IMD MUTE CC FREEZE UNDEF none Set up the F1 Function key action F2 NATIVE SCAN NATIVE ASPECT BLUE ONLY MONO MA...

Страница 23: ...ETWORK Select an IMD protocol IMD ID 0 0 to 255 unit ID number for Dynamic IMD Tally Set the ID number for the IMD IMD NAME Name Set the ID name for dynamic IMD Tally BAUD RATE 115200 2400 4800 9600 1...

Страница 24: ...600 V Aspect ratio 15 9 Display Area mm 153 6 H x 90 0 V Viewing Angle 150 H x 170 V Color Depth 16 7M colors Contrast Ratio 800 1 Brightness 400 cd m2 typical Response Time 30 ms typical Video Input...

Страница 25: ...Page 25 Figure 3 1 RM 3270WS 3G Block Diagram...

Страница 26: ...Page 26 Figure 3 2 RM 3270WS 3G2 Block Diagram CVBS SDI CVBS SDI...

Страница 27: ...tor Phones are not recommended due to their smaller screen size which would require more scrolling The Chrome web browser is recommended for speed and compatibility First Time IP Assignments The RM 32...

Страница 28: ...s IP Address into the browser s address bar and press the Enter key to access the web server Select whether Monitor 1 or Monitor 2 settings are to be changed in the upper left bar or check the Apply...

Страница 29: ...Page 29 Figure 4 2 Status Page IP Address...

Страница 30: ...rameter name indicates that the parameter is only local for the currently selected monitor screen Otherwise the parameter is global and the setting applies to both screens Click the SET button to chan...

Страница 31: ...Page 31 Video Display Page Figure 4 4 Video Display Page Input Setup Page Note that IN2 is only present on the RM 3270WS 3G2 but is not present on the RM 3270WS 3G Figure 4 5 Input Setup Page...

Страница 32: ...RKER OFF ON setting enables or disables the visibility of all markers on the screen The settings of each marker are retained as the last change made from either the OSD Menu or this Network Control Pa...

Страница 33: ...ne and AUDIO OUT outputs METER SELECT controls which and how many channels are metered independently of the SPEAK er OUT selections An S icon following a parameter name indicates that the parameter is...

Страница 34: ...lose Caption Page Config Page An S icon following a parameter name indicates that the parameter is only local for the current selected monitor Otherwise the parameter is global and the setting applies...

Страница 35: ...Temp Menu COPY FROM specifies a USER profile is to be made from it The USER color profile can be modified as desired from within the OSD Menu In Figure 4 10 Color Space has been expanded to show the...

Страница 36: ...1 F2 is shown expanded to see choices available for either function key s assignment Some functions such as FREEZE can only be initiated by a function key if there is no menu setting for enabling the...

Страница 37: ...via the network with this page or with the OSD IMD Menu Both are retained in the monitor s memory and IMD PROTOCOL settings of LOCAL vs NETWORK decides which one is displayed In Figure 4 12 Tally Sou...

Страница 38: ...n needs The first three GATEWAY number blocks usually match the first three number blocks of the IP ADDRESS and the last number is usually 1 The LOCK NUMBER is only needed in certain software installa...

Отзывы: