Page
9
inputs. Note that SDI 1 is selected by default whenever the AMP1-8-M is
powered up, or
b.
Press and hold either of these LED button for three seconds to switch
between monitoring channels 1 – 8 or channels 9 – 16 for the selected
SDI source.
10.Adjust: Pressing and holding this button for approximately three seconds opens
the menu system you may use to customize the operation of the AMP1-8-M.
Rear Panel
Figure 1–2: Rear Panel Layout
1.
Power: The AMP1-8-M uses a standard IEC power cord for the 100 to 240 VAC
±10%, 50/60 Hz power connection.
2.
3G/HD/SD-SDI Inputs: These two BNC connectors accept the 3G/HD/SD-SDI
input signals.
3.
3G/HD/SD-SDI Outputs: These BNC connectors output regenerated replicas
of the two 3G/HD/SD-SDI input signals.
4.
Selected 3G/HD/SD-SDI Re-Clocked Output: This BNC connector re-clocks
the selected 3G/HD/SD-SDI input signal.
5.
Ethernet: The AMP1-8-M does not currently use the Ethernet port except during
factory programming. For normal operation, the port may be connected to a LAN
or disconnected. In future releases, Wohler may or may not release remote
control software for this unit, such as is used in the AMP1-16-M.
6.
Analog Outputs: These XLR connectors provide two channels of balanced
analog outputs. The source of these signals is the mix of audio monitored by the
internal speakers.