Maintenance
41
EN
7.1
Replace hose
Unwind the hose to be replaced completely
and release the quick-release coupling.
WARNING!
Exercise due care and attention when pulling out
the hose: The last winding could be under tension
and cause the hose to make a whipping move-
ment.
Insert the replacement hose in the quick-
release coupling and wind the hose evenly on-
to the viper.
7.2
Replace battery
The digital meter counter is fitted with a long-life
battery that only needs to be replaced every 5-10
years. The battery status is shown by the battery
status indicator in the display. To replace the bat-
tery proceed as follows:
Fig. 34: Replace battery
Pull the frame away from the display.
Carefully grip the display and pull it out along
with the PCB and battery.
Remove the battery from the rear of the PBC
and connect a new 3.6 V lithium battery.
Place the display along with the PCB and
battery back in the original position.
Put the frame of the display back in its position
and press it securely into place.