R200
Industrial Cellular Router User Manual
www.wlink-tech.com
27
Figure 3-14
Serial App Setting GUI
Table 3-12
“Serial App” Instruction
Parameter
Instruction
Serial to TC/IP
mode
Support Disable, Server and Client mode. Such as Client.
Server IP/Port
IP address and domain name are acceptable for Server IP
Socket Type
Support TCP/UDP protocol
Socket Timeout Router will wait the setting time to transmit data to serial
port.
Serial Timeout
Serial Timeout is the waiting time for transmitting the data
package that is less the Packet payload. If the last package
equals to the Packet payload, Serial port will transmit it
immediately. The default setting is 500ms.
Packet payload
Packet payload is the maximum transmission length for
serial port data packet. The default setting is 1024bytes.
Heart-beat
Content
Send heart beat to the defined server to keep router online.
Meantime, it
’s convenient to monitor router from server.
Heart beat
Interval
Heart beat interval time
Baud Rate
115200 as default
Parity Bit
None as default
Data Bit
8bit as default
Stop Bit
1bit as default