WL-G530 Series Router User Manual
57
Parameter
Instruction
Input from 0 to 30000ms. (0=generate pulse without delay)
Low
Available when enable Pulse in Alarm On Action/Alarm Off Action.
In Pulse Output mode, the selected digital output channel will
generate a square wave as specified in the pulse mode parameters.
The low level widths are specified here.
Input from 1 to 30000 ms.
High
Available when enable Pulse in Alarm On Action/Alarm Off Action.
In Pulse Output mode, the selected digital output channel will
generate a square wave as specified in the pulse mode parameters.
The high level widths are specified here.
Input from 1 to 30000 ms.
Output
Available when enable Pulse in Alarm On Action/Alarm Off Action.
The number of pulses, input from 0 to 30000. (0 for continuous pulse
output)
SMS Trigger
Content
Available when enable SMS Control in Alarm Source.
Input the SMS content to enable
“
Alarm On Action
”
by SMS (70
ASIC II char max).
SMS Reply
Content
Input the SMS content, which will be sent after DO was triggered.
(70 ASIC II char max).
Number 1
SMS receiver phone number.
Number 2
SMS receiver phone number.
Step 3 Please click ”save” to finish.
DO might be customized pulse width ratio: T1, T2 duration and n value.
2.9.10
Configuration Setting
Step 1 Please click “ Administrator> Configuration ” to do the backup setting
Содержание WL-G530 Series
Страница 24: ...WL G530 Series Router User Manual 24...
Страница 68: ...WL G530 Series Router User Manual 68 3 Set the PC to DHCP 4 Check the Ethernet status and ping test...
Страница 71: ...WL G530 Series Router User Manual 71 Finally we can see the results by connect to router WIFI...
Страница 78: ...WL G530 Series Router User Manual 78 Navigate to VPN Tunnel GRE 3 8 2 OpenVPN...
Страница 87: ...WL G530 Series Router User Manual 87 End...