19
EN
1.3 Gas cartridge Express 444 connection
(Adapter Express 444 optional,
Art.No.: 6.006.080
)
Before mounting the adapter Express 444 for cartridge Express 444 from Guilbert
Express unscrew the handle (
5
) counterclockwise with your hand. Then, dismantle the
adapter CV360 (
8
) with the included wrenches. (Left hand thread, dismantling in
clockwise direction). Use one wrench (wrench size 14 mm) to hold the threaded screw
connection R 1/4" (
6
). Ease and unscrew the pre-assembled adapter CV360 (
8
) with the
second wrench (wrench size 17 mm).
Now, screw on the adapter Express 444 (
10
). Tighten the swivel nut counterclockwise.
For this both wrenches have to be used, too. Use one wrench (wrench size 14 mm) to
hold the threaded screw connection R 1/4" (
6
) and tight the swivel nut (
7
) with the
second wrench (wrench size 17 mm).
Finally screw on the handle (
5
) with your hand in clockwise direction.
Pay attention to the warning. Do not use any cartridges which are dented. Ensure that
the sealing (
11
) is in place and in good condition.
Remove the white protective cap of the gas cartridge. Hold the cartridge (
12
) tightly and
insert it plain into the threaded screw connection of the adapter Express 444 (
10
).
Gently screw the gas cartridge in clockwise direction into the threaded
screw connection. Be careful not to fit the gas cartridge Express 444 (12)
skewed.
Temperature range when using cartridges is +10°C to +35°C. (50°F to 95°F)
!
1.4 Connection to mains gas supply
The unit can be connected to the mains gas supply when the gas pressure is within the
range of 18 - 25 mbar for natural gas or 28 - 57 mbar for propane/butane gas. A DVGW-
safety tubing for threaded screw connection (1/4“) can be connected to the threaded screw
connection G 1/4" (
6
) of the powerjet 2 directly. For a DVGW-safety tubing with push-fit
connection the connector with swivel nut (
7
, included ) has to be mounted to the threaded
screw connection G 1/4" (
6
).
A DVGW-proven or other gas approved pressure regulator (50mbar) must be used for
liquid gas.
Before mounting the tubing connector with swivel nut (
7
) (or DVGW-safety tubing for
threaded screw connection) unscrew the handle (
5
) counterclockwise with your hand.
Then, dismantle the adapter CV360 (
8
) with the included wrenches. (Left hand thread,
dismantling in clockwise direction). Use one wrench (wrench size 14 mm) to hold the
threaded screw connection R 1/4" (
6
). Ease and unscrew the pre-assembled adapter
CV360 (
8
) with the second wrench (wrench size 17 mm).
Now, screw on the tubing connector with swivel nut (
7
) (or DVGW-safety tubing for
threaded screw connection). Tighten the swivel nut counterclockwise. For this both
wrenches have to be used, too. Use one wrench (wrench size 14 mm) to hold the
threaded screw connection R 1/4" (
6
) and tight the swivel nut (
7
) with the second wrench
(wrench size 17 mm).
Finally screw on the handle (
5
) with your hand in clockwise direction.
Do not seal up the thread of the gas connection (6) with Teflon tape etc.
!