17
EN
5. Routine service and maintenance
Ensure that the sealing (
7
) is in place and in good condition. Inspect every time you use
the powerjet. Replace the sealing if damaged or worn.
(Sealing for powerjet,
Art.No.: 6.005.010
)
6. Cleaning / assembly and disassemly of the burner tube
Shut off the gas controller (
1
) completely (Turn the gas controller (
1
) in clockwise direction
to the stop position). Allow sufficient time for burner orifice (
2
) and burner tube (
3
) to cool
down. Screw the gas cartridge out of the powerjet. The burner can be cleaned with
customary commercial disinfectants.
Disassembly of the burner tube (
3
) :
The powerjet is equipped with a bayonet quick fitting connection.
Turn the burner tube (
3
) 90° counterclockwise out of the locking device.
Pull the burner tube (
3
) out of the powerjet.
Assembly of the burner tube (
3
):
Push the burner tube into the powerjet and turn 90° clockwise into the locking device.
7. Warranty
The powerjet is covered under our two-year manufacturer warranty against any
manufacture defects in material. The WLD-TEC warranty guarantees powerjet under
normal usage conditions and does not cover any damages as a direct result of
user misuse. The warranty is void upon any unauthorized servicing, disassembly or modi-
fications.
8. Technical Data
Type
powerjet
Gas cartridge
connection
Gas types:
liquid gas (propane/butane)
gas cartridges with 7/16“ x 28 UNEF thread
e.g.
CG1750
from
Campingaz
Connected load:
0,12 kg / h liquid gas
Temperatures
Flame temperature:
1350 °C on liquid gas
Temperature threshold
level:
1,54
kW
liquid
gas
Mechanical
Measurements:
W = 150 mm
H = 180 mm
Weight:
300 g