The burner shuts-off due to overtemperature frequently
In case of overtemperature increase the air ventilation or change the operation site.
The IR-Sensor cannot be activated
It is possible to adjust the sensor range to 0 mm or more than 70 mm. Then the IR-Sensor
is out of range and cannot be activated. In that case, increase or decrease the IR-Sensor
range at the function for sdjusting the IR-Sensor detection range
(see paragraph 2.3)
Green LED “Button“, “Standard“ or „StartStop“ blinks 2x
Ignition faliure
(see paragraph 4)
Green LED “Button“, “Standard“ or „StartStop“ blinks 3x
Flame faliure
(see paragraph 4)
Green LED “Button“, “Standard“ or „StartStop“ blinks 4x
Overtemperature
(see paragraph 4)
Green LED “Button“, “Standard“ or „StartStop“ blinks 5x
This message indicates that the burner head is removed. Further operation is possible after
the burner head is reinstalled.
(see paragraph 4)
Amber LED “Burner head HOT / BHC“ is on permanently
The residual heat display is active. DO NOT TOUCH the burner head. Can cause burns!
(see paragraph 3)