34
•
In operating mode “Button“ or Pedal “Start-Stop“ flame burns 30 seconds, only
BHC time limit is active, LED “Burner head hot / BHC“ is flashing.
The burner head is clogged and must be cleaned.
(see paragraph 4.2, 5.5 & 6.1)
.
•
Flame too small / large / soft
Check the position of the air and gas adjustment.
Check if the correct nozzle is installed.
Nozzle N: natural gas, 18 - 25 mbar
Nozzle P, B: propane / butane gas, 47.5 - 57.5 mbar
Check if the drilling of the active nozzle is blocked
(see paragraph
1.1)
. Unscew the active nozzle. If the drilling is blocked clean with a
brush or compressed air.
Troubleshooting guide
•
The green LED "Standard" or "Start-Stop" does not light up
Check for correct connection and specification of the power adapter.
Ensure that the original power adapter is used.
Specifications: 9 V / DC, 1.3 A
Polarity:
•
The tethered foot pedal does not work
Check for correct connection of the foot pedal. Ensure that the foot
pedal socket and plug is not twisted or broken.
•
No Flame
In case of ignition or flame faliure check if the burner head is clogged.
Verify the input pressure of the used gas. Ensure that the correct
nozzle is installed in the unit.
Nozzle
N: natural gas, 18 - 25 mbar
Nozzle P, B: propane / butane gas, 47.5 - 57.5 mbar
•
LED “Burner head HOT / BHC“ flashes / Inspection of the
burner head (clogging)
Take care that there are no liquids or other substances
at the Bypass (area between the inner and the outer ring)
Especially remove substances in the marked areas at
the electrodes. If there are contaminants in this area,
the flame cannot encircle the electrodes correctly.
Clean this areas with a brush. The burner head can be
cleaned with customary commercial disinfectants,
or it can be sterilized in an autoclave or washed in a
dishwasher.
Bypass
Electrode