24
Translation of the original operating instructions
DUO
MIX
270
DM270_BAoDB_en_1507 • rs
Machine description
Operating mode
Flush B
0
0
0
I
Flush A+B
0
0
I
I
Stop
0
0
0
0
Open and close the flushing levers multiple times in alternation during flush-
ing, in order to ensure that each component is flushed through separately.
Finally, flush with both levers in the flushing position.
3.9 Flushing pump
In flushing mode the flushing pump con-
veys the flushing agent from the flushing
agent tank via the mixing unit to the spray
gun. A manifold is mounted between the
material outlet of the flushing pump and
the mixing unit for distributing the flushing
agent to the A-component and B-compo-
nent sides.
No. Designation
1
Muffler
2
Air motor
3
Fluid pump
4
Safety valve
5
Material outlet
6
Suction pipe
1
2
3
5
4
6
Fig. 13: Flushing pump