Progressive Type Safety Gear
WSGB04, WSGB10
Operating instructions
Blatt/
sheet
D7AMMGB.25
Datum/
date
11.04.2003
Stand/
version D-16.02.2010
Geprüft/
approved WAT/MZE
Änderungen vorbehalten!
Subject to change without notice!
(
1
) Connect the contact
(
2
) Test the safety gear contact function - adjust
if necessary
(
3
) Adjust the switch horizontally on its fixing
bracket.
Adjusting dimension: 3-5 mm from the
guard peak
The contact must brake just before safety
gear gripping!
3.8
Safety gear contact
-
use category:
AC 15, A300
U
e
/I
e
240V (3A)
-
thermal current:
I
the
= 10A
-
insulation voltage: U
i
= 250 VAC (EN81)
300 VAC (ASME)
-
protection type:
IP 43
-
approved in accordance: VDE 0470
IEC/EN 60947-5-1
(
1-3
)
Safety gear contact
3.7
Electrical installation of the safe-
ty gear contact
Work involving electrical equipment
should only be carried out by an electrical
fitter or qualified personnel.
Before carrying out work, switch off all
voltage to installation equipment.
Take note of the following when laying the
connection cable:
• that the single polarity cables have dou-
ble insulation
• the use and laying of cables is governed
by the EMC
The safety gear contact opens the lift in -
stal lation’s remotely controlled safety cir-
cuit.