Startup and operation
TPM
+
en-18
4022-D018396
Revision: 07
6
Startup and operation
6.1
Safety instructions and operating conditions
Read the general safety instructions before beginning work (see Chapter 2.7 "General safety
instructions").
Wearing hearing protection in the vicinity of the servo actuator is recommended.
6.2
Data for the electrical startup
The specified data is intended for the electrical startup.
In some servo controllers, there is a dependence between the individual parameters. We would
be glad to assist you in finding the correct entries.
We provide adjusted and certified quick start guides for several servo controllers. In these
guides you will find the adapted parameter lists for the relevant servo converters.
For further information, please visit our website at http://wittenstein-alpha.de or contact our
Customer Service: [email protected]
This data reflects the technical characteristics and the limit values of the standard engines of the
TPM
+
- series in general units. Possible restrictions due to the gearhead can be found in the data
sheet of your servo actuator.
Select the data for the TPM
+
- version you are using.
-
Chapter 9.4.4 "Motor data, TPM
-
Chapter 9.4.5 "Motor data, TPM
-
Chapter 9.4.6 "Motor data, TPM
-
Chapter 9.4.7 "Motor data, TPM
-
Chapter 9.4.8 "Motor data, TPM
-
Chapter 9.4.9 "Motor data, TPM
-
Chapter 9.4.10 "Motor data, TPM
Improper use can cause damage to the servo actuator.
Ensure that
-
The
ambient temperature
does not drop below 0 °C or exceed
+40 °C,
-
The
surface temperature on the gearhead
does not 90°C,
-
The
surface temperature on the engine
does not 115°C,
-
The
installation altitude
is not above 1000 m NHN.
For other conditions of use, consult our Customer Service department.
Use the sensor only up to its maximum limit values, see Chapter 9.4
"Technical specifications".
Only use the servo actuator in a clean, dust-free and dry environment.
Operate the servo actuator only in the mounting position that is specified
on the identification plate.
The servo controllers of the different manufacturers generally use an
individual annotation of the data.
If the data is disregarded, the drive and/or the servo controller may be
damaged.
Observe the listed units
precisely
and check their conformance with the
units of the servo controller.
If the units differ, make the necessary adjustment accordingly.
Содержание TPM dynamic
Страница 1: ...4022 D018396 07 4022 D018396 Revision 07 TPM dynamic high torque power Operating Manual ...
Страница 44: ...Appendix TPM en 44 4022 D018396 Revision 07 Option N and K signal pin assignment 1 ...
Страница 45: ...TPM Appendix Revision 07 4022 D018396 en 45 Option S and M signal pin assignment 1 ...