TPM
+
Assembly
Revision: 07
4022-D018396
en-15
5
Assembly
Read the general safety instructions before beginning work (see Chapter 2.7 "General safety
instructions").
5.1
Preparations
Clean/de-grease the output shaft /output flange of the servo actuator with a clean, lint-free
cloth moistened with a suitable grease-dissolving but non-aggressive cleaning agent.
Dry all fitting surfaces to neighboring components in order to achieve the proper friction values
of the screw connections.
Check the fitting surfaces additionally for damage and impurities.
5.2
Mounting the servo actuator onto a machine
Many electronic components are sensitive against electrostatic
discharge (ESD). This concerns in particular integrated circuits (IC),
semiconductors, resistors with a tolerance of less than one percent as
well as transistors and other components such as encoders.
Observe the directives concerning ESD protection.
Pressurized air can damage the servo actuator seals.
Do not use pressurized air to clean the servo actuator.
The servo actuator is compliant for every mounting position; the
lubricant quantity, however, is dependent on the mounting position.
The mounting position and the lubricant that has been filled in is
indicated on the identification plate (see Chapter 3.1 "Identification
plate").
Mount the servo actuator only in the specified mounting position.
Observe the safety and processing instructions for the threadlocker to be
used.