3.3.1 Installation at cyber
®
reaction wheel starter kit
To do this, perform the following steps:
Secure the reaction wheel (I) in the required axis configuration to the starter kit (G) using
screws (H).
•
If the cyber
®
reaction wheel is to be
detached from the starter kit again, do
not
use threadlocker.
•
Fasten the reaction wheel to the
starter kit using the fastening
screws H.
•
Make sure the unused second
connector (red marking) is protected
against contact with conductive
components.
3.3.2 Establishing the power supply
1. Connect the USB cable included with the starter kit to the PC on which the cyber
®
reaction
wheel assistant has been installed and to the USB port A (see section 2.2.5.1) on the starter
kit. The reaction wheel is then already supplied with voltage via the USB port.
2. Set the UART uC / USB PC switch at the starter kit to USB PC
3. There is also the option of connecting an external supply voltage to screw terminals E in
addition to the USB voltage as described in section 2.2.5.4. This allows operation under all
load conditions. Observe the maximum permitted input voltage according to section 2.1.5.
3.3.3 Establishing a connection
1. Open the cyber
®
reaction wheel assistant with a double-click
2.
Select Device ReactionWheel[…]
3. Press "Connect" to establish a connection
Figure 1.17: Establishing a connection to the cyber
®
reaction wheel 2
3
2
Fastening screws
M
A
= 0.11 Nm