Project planning guide
cyber
®
reaction wheel 2
en-26
Doc. no.: 5022-D060586
Revision: 02
2.3.5.2 Setting speed and current limits
The necessary parameters are listed in the Limits and Power screen of the cyber
®
reaction wheel
assistant. The CHM-Help for the parameter can be accessed by clicking on the corresponding
field and pressing F1 or clicking the question mark circled in blue.
Figure 1.16: Screen for setting system limits, e.g., current limits
Index
Description
upper limit
lower limit
Default
Access
0x3A0B Max. DC current
0.9 A
0.9 A
0.9 A
ro
0x6073
Maximum motor
current
0.46 A
0.46 A
0.46 A
ro
0x3A04
Maximum power
electronics current
0.46 A
0.46 A
0.46 A
ro
0x3A45
Maximum user phase
current
0.46 A
0 A
0.46 A
r/w
0x3610
Used current limit
-
-
Min(0x60
73,0x3A0
4,0x3A45)
ro
Table 21: Parameters for setting the system limits