background image

HMD

 

SERIES

 

 

F-41142 (10-09) 

 

 

8. 

Install tray slides in the cabinet. 

 
9. 

Ensure that the hook on the end 

 

of the tray slide is up. 

 

CLEANING:

 

The cabinet should be thoroughly 
cleaned prior to putting into service. 
 

Use a mild soap and water solution to 
clean the interior of the unit.  Never use 
harsh chemicals or abrasive pads to 
clean the unit. 
 

 

(Fig. 2) 

 
 
 

ELECTRICAL REQUIREMENTS 

 

LOCATION:

 

For efficient cabinet operation, choose a 
location that will provide easy loading 
and unloading without interfering with 
the final assembly of food orders. 
 
The installation location must allow 
adequate clearances for servicing and 
proper operation.  

(Fig. 2) 

 

 

 

1-617-770-3000 

ELECTRICAL CODES & STANDARDS: 

The cabinet must be installed in 
accordance with: 
 

In the United States of America: 

1. 

State and Local Codes. 

2. 

National Electrical Code, ANSI/ 

 

NFPA-70 (latest edition.)  Copies 

 

may be obtained from:  The 

 

National Fire Protection 

 

Association, 1Batterymarch Park, 

 

Quincy, MA 02269.  

www.nfpa.org

 

 

 

In Canada: 

1. 

Local Codes. 

2. 

Canadian Electrical Code, CSA 

 

C22.1 (latest edition.)  Copies 

 

may be obtained from:  The 

 

Canadian Standard Association. 

 

www.csa.ca

 

 

 

All 

cabinets 

are 

equipped with a three-prong plug.  It 
is imperative that this  plug must be 
connected into a properly grounded 
three-prong receptacle.  If the 

ELECTRICAL CONNECTIONS: 

The cabinet is factory wired for either 
110/120 volt or 208/240 volt, single 
phase operation.  All 110/120 volt 
cabinets are equipped with a 8 foot cord 
and NEMA 5-15 plug as standard 
equipment.  All 208/240 volt cabinets 
are equipped with a 8 foot cord and 
NEMA 6-15 plug.  Refer to wiring 
diagrams in the back of this manual. 
 
The cord and plug supplied is a suitable 
durable cord with a molded three-prong 
plug, and is provided with a proper 
strain relief. 
 

Содержание 1826-13-HMD

Страница 1: ...tco com 2009 Wittco Foodservice Equipment F 41142 10 09 INSTALLATION OPERATION MANUAL HMD SERIES HumidiHeat HOLDING TRANSPORT CABINETS MODELS 1826 5 HMD 1826 13 HMD 1826 15 HMD For additional informat...

Страница 2: ...MANUAL FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITYOF THIS OR ANY OTHER APPLIANCE WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MA...

Страница 3: ...1 GENERAL 3 INTRODUCTION 3 INSTALLATION 3 ELECTRICAL REQUIREMENTS 4 LOCKOUT TAGOUT PROCEDURE 5 OPERATION 6 CONTROLS 6 OPERATING INSTRUCTIONS 6 SHUT DOWN 7 CLEANING 7 STAINLESS STEEL CARE 8 TROUBLESHOO...

Страница 4: ...ment immediately Fig 1 Fig 1 UNPACKING The Cabinet was inspected before leaving the factory The transportation company assumes full responsibility for safe delivery upon acceptance of the shipment Imm...

Страница 5: ...ocal Codes 2 National Electrical Code ANSI NFPA 70 latest edition Copies may be obtained from The National Fire Protection Association 1Batterymarch Park Quincy MA 02269 www nfpa org In Canada 1 Local...

Страница 6: ...E INJURY OR DEATH Always perform the LOCKOUT TAGOUT PROCEDURE before removing any sheet metal panels or attempting to service this equipment The Lockout Tagout Procedure is used to protect personnel w...

Страница 7: ...rature range is from 80 F to 200 F OPERATING INSTRUCTIONS 1 Connect to proper electrical supply as indicated on data plate 2 Fill water into Water Reservoir Reservoir holds approx 1 gallon or 3 78 lit...

Страница 8: ...the Temperature Control Knob counterclockwise to the OFF position 2 Turn the Humidity Control Knob counterclockwise to the OFF position 3 Unplug unit from the electrical power supply Always UNPLUG EL...

Страница 9: ...sed or chloride containing cleaning solutions which will break down the protective film 4 Never rub in a circular motion Always rub gently in the direction of the steel grain 5 Never leave any food pr...

Страница 10: ...ks moisture Damaged door gasket or door requires adjustment Contact Authorized Service Provider Door not properly shut Shut door Door gasket damaged Contact Authorized Service Provider Heating element...

Страница 11: ...N mm DEPTH IN mm WIDTH IN mm SHIPPING WT Lb kg VOLTS WATTS AMPS 1826 5 HMD 32 375 34 25 25 125 170 77kg 120 1200 10 1826 13 HMD 59 375 1700mm 34 25 857mm 25 125 724mm 340 154kg 120 1200 10 1826 15 HMD...

Страница 12: ...HMD SERIES F 41142 10 09 11 WIRING DIAGRAM...

Отзывы: