29
CONNEXION OF THE DIFFERENT ELEMENTS
The installation of this appliance and the connection to the electrical network should be made by
an electrician perfectly aware, and in respect of the normative regulations
Connection of cooking zones
Each connector of the cooking zones, is located by a sticker with the classification from 5 to
8 corresponds to:
5: Heating zone 1100 W / Glass diameter 270mm
7: Heating zone 2300 W / Glass diameter 300mm
The fingertouch electronic
is located by “C” on the connector
On the technical box, near the female connectors are written:
5-6-7-8-C
.
Connect the fingertouch on the “C” of the technical box.
Connect the heating zones with the corresponding number on the technical box.
To connect easily, begging with the biggest number of the heating zone.
Example:
Notice:
- Choose one of below positions. If you choose another position the product can be damaged. The
guarantee no longer applies if another position is chosen.
- The cooking zone cables cannot be shortened or extended.
- The manufacturer / distributor cannot be held responsible for person and/or product damages if
above-mentioned requirements are not kept.
- The glass size with regards to heat insulation is always 9 cm larger than the induction zone size.
- Please be aware if you want another combination of zone sizes:
- A given zone size CANNOT be replaced by a smaller since the effect will be too high and cause
damage.
- A given zone size can be replaced by a bigger. This will not increase in effect but result in a better
heat distribution using larger cookware.
- It is only recommended to choose a zone size one time bigger than indicated with regards to the
limited effect the zone will have if it is too big. E.g. an 18 cm zone can be replaced by a 21 cm
zone.