Alignment

 

mode:

This mode allows for optimum alignment of the LIGI based on a variable flash frequency of 

the LEDs on the receiver.

Error messages:

The LIGI has an internal error diagnosis function which indicates errors by means of an LED 

code depending on the type of error. In the event of an error, the LIGI switches to safe mode 

and the door can then only be operated in “dead man” mode.

Electrical connection:

Operating mode

The connections are made depending on the version according to the supplied circuit 

diagram.

Important note: The sync cable (white wire) is an internal connection between the 

transmitter and receiver which must not be connected in the controller!

Transmitter

power supply = OK 

blanking = off

power supply = OK 

blanking = on

Test  

(LEDs flashing alternately)

Receiver

Free detection zone

Interrupted detection zone

Test  

(LEDs flashing alternately)

Legend

LED lit

LED flashing

LED off

green

yellow red

Transmitter

Receiver

Содержание LIGI-07

Страница 1: ...Sensoric Sensoric GmbH Berlin www witt sensoric de 1 Sensoric Original operating instructions Safety light curtain LIGI 07...

Страница 2: ...05 open is normal operation test low or high Beam geometry A continuous high detection capability C standard compliant detection capability Active light beams Active detection zone in mm F Function 00...

Страница 3: ...sing barriers barriers that are used solely for vehicle traffic and dangerous machines that are not doors During mounting installation and commissioning it must be ensured that the pho to switch syste...

Страница 4: ...sured that the door control system checks the safety light curtain versions with a test input once per door cycle To do so the control system must trigger the test input on the transmitter for at leas...

Страница 5: ...If the test input of the light curtain is activated for longer than 15s the light curtain switches into alignment mode The signal reserve can be optimised in alignment mode by alternately rotating the...

Страница 6: ...d the door can then only be operated in dead man mode Electrical connection Operating mode The connections are made depending on the version according to the supplied circuit diagram Important note Th...

Страница 7: ...The more the level increases the faster the flash frequency of the red LED will be When the maximum flash frequency is reached the light curtain is optimally aligned and can be fastened in place For...

Страница 8: ...flashes 2x long pause Check output cable overload wrongly con nected cable defective output on light curtain defective Error in sync cable Yellow LED flashes 3x long pause Check sync cable white may...

Страница 9: ...y If the previous step has been carried out correctly the green LED on the receiver will be continuously on and the red LED will flash The reference values will then be pro grammed It is essential to...

Страница 10: ...n the transmitter and receiver is connected with 10 30 V DC for longer than 15s and less than 25s all the saved reference values from the programming process will be actively deleted i e the factory s...

Страница 11: ...nge of 0mm to 300mm above the ground 2 A test object with an edge length of 200mm must be continuously detected over a range of 0mm to 2500mm above the ground The test bodies should be moved from bott...

Страница 12: ...t be replaced Furthermore please check detection ability on a regular basis as per manual page 11 If light curtains are replaced they must only be replaced by identical light curtains or by other safe...

Страница 13: ...50Hz PNP output High level NPN output Low level solid state relay SSR low resistance Aperture angle Approx 5 Detection capability 0 to 300mm detection object 50mm version C 300 to 2500mm detection obj...

Страница 14: ...afety 100klux Housing material Aluminium profile fully filled with 2K epoxy resin Connection Pig tail M8 plug 6 pin L 130mm Degree of protection IP67 as per EN 60529 Operating temperature 20 to 60 C S...

Страница 15: ...the output P01 after max 100ms switch from low to high level N01 after max 100ms switch from high to low level OSE This version is not tested solid state relay SSR after max 100ms change from high re...

Страница 16: ...ung zwischen Empf nger und Sender Test aktiv bei 10 30VDC Transmitter Receiver 10 30VDC 0V GND Test Alignment input not assigned not assigned Sync 10 30VDC 0V GND SSR output SSR output not assigned Sy...

Страница 17: ...High level or switch closed T03 Test Low level or switch closed T04 Test High level or switch open 0V GND 10 30V 10 30V test high level 0V GND test low level open standard operation Test input Test i...

Страница 18: ...45 45 45 45 45 45 45 45 45 45 45 45 45 7 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 45 7 45 2363 indicator LED 2363 indicator LED 2430 aktive detection zone 5...

Страница 19: ...Version A Version C 5 45 45 45 45 45 45 45 45 45 45 45 118 45 45 45 45 45 45 45 45 45 45 45 45 45 45 5 45 45 45 45 45 45 45 45 45 45 45 118 45 45 45 45 45 45 45 45 45 45 45 45 45 45 5 45 45 45 45 45 4...

Страница 20: ...Volume mm Anzeige LED 7 22 5 22 5 2518 24 24 45 2388 aktive Schutzfeldh he 55Kan le 12 4 10 45 A A 1 5 1 G 1 5 1 H 1 5 1 A B C LIGI 07 55 Kan le Gez Kontr Datum Name 10 03 2017 10 03 2017 pollak Brech...

Страница 21: ...nie 2006 42 EG RoHS Directive 2011 65 EU EMC Directive 2014 30 EU Machinery Directive 2006 42 EC Folgende Normen oder Teile dieser Normen wurden angewendet Following standards or parts of these were a...

Страница 22: ...Sensoric Sensoric GmbH Berlin www witt sensoric de 22 Sensoric Notes...

Страница 23: ...Sensoric Sensoric GmbH Berlin www witt sensoric de 23 Sensoric...

Страница 24: ...www witt sensoric de 24 Sensoric Sensoric Witt Sensoric GmbH Ernst Lau Stra e 12 12489 Berlin Germany Tel 49 0 30 75 44 94 120 Fax 49 0 30 75 44 94 123 sales witt sensoric de www witt sensoric de Wit...

Отзывы: