The operation of the light curtain is to be tested as follows once it has been mounted.
1. A test rod with a diameter of 50mm must be continuously detected over a range
of 0mm to 300mm above the ground.
2. A test object with an edge length of 200mm must be continuously detected
over a range of 0mm to 2500mm above the ground. The test bodies should be
moved from bottom to top during these tests.
Top view:
Door and recommended light curtain layout of T=transmitter and R=receiver
R
T
T
T
R
R
Figure 2
With door function
(Blanking function)
Figure 1
Without door function
(Blanking function)