Operating instrutions
Please contact a specialist technician should it not be possible to eliminate the fault.
13 Disposal
Do not dispose of the pump and/or individual parts in household waste!
Dispose of the pump and/or parts in an environmentally conscious way.
To do this, please contact a public or private disposal organisation.
A list of the materials used in our products is provided in the download
area of our website. (www.wita.de)
Note
Error indication or
Error code in the display
of the pump
E20
E40
Causes
Rotor blocked
Overcurrent protection circuit
remedy
Switch the pump off and secure against being
switched back on.
If possible, close the shut-off valve in front of and
behind the pump or drain the water.
Depending on the operating condition of the system,
hot water can escape! Risk of burns!
Unscrew the 4 head cap screws and remove the
pump head by loosening the motor head.
Pump impeller must be able to rotate easily.
Remove any impurities or foreign bodies and reas-
semble the pump.
If the error persists, the pump must be replaced.
Press any key or disconnect the pump for minimum
1 minute from the power supply
Is the error still existing the pump must be replaced