15.2. PROGRAMMING THE CONTROLLER
[D000721] The drive unit is programmed using the “OK”, “ESC”, “+”, and “-” buttons located on the drive unit controller and the digital display. To access the control-
ler menu, enter the four-digit installer key. Press “+” or “-” to start entering the key. The factory installer key is 1234.
No.
Function
Range
Factory
setting
Definition
Description
Level
1
2
1
Pr
1, …, 99
-
Remote control programming
Programming or removing one remote control. Removing all remote controls – the PF function.
2
bA
Optical barrier
Optical barrier settings
tP
0, 1, 2, 3, 4
1
Operating modes
Optical barrier operating modes:
0 – Photocells are inactive
1 – No reaction when opening, reverse motion when closing
2 – Stop when opening, reverse motion when opening
3 – No reaction when opening, stop when closing
4 – Stop when opening, stop when closing
AF
oF, 0.1, …, 9.9
oF
Closing after interrupting the bar-
rier path
Time in minutes after which the gate will start closing when the barrier is interrupted
Ft
on/oF
oF
Barrier self-test
Starts the photocell self-test before each movement of the gate
3
cr/Cr
Gate calibration information
Informs whether the gate is calibrated (Cr) or not (cr). 5x OK resets the gate calibration
4
Au
oF, 0.1, …, 9.9
oF
Automatic closing
Time in minutes after which the gate will start closing automatically
5
UP
1, …, 20
-
Overload setting
Gate operating force adjustment. The parameter is selected automatically during the calibration
6
Fr
oF, 1, …, 40
40
Wicket – partial opening of the gate Width setting determining the width to which the gate opens when the wicket mode is activated
7
SE
Controller inputs
Controller input setting
St
on/oF/rE
on
Stop
on – stop input active
oF – stop input active – stop when activated
rE – stop input active – reverse when activated
SP
0, 1, 2
0
Resistive safety edge input
0 – safety edge input inactive
1 – reverse when opening, reverse when closing
2 – no reaction when opening, reverse when closing
So
Ot/OZ/3F/U
Ot
Control input 1
Ot – open
OZ – open / close
3F – open / stop / close / stop
U – open partially
Su
ZA/UZ
UZ
Control input 2
ZA – close
UZ – open partially / close
8
bL
Controller interlocks
Controller interlock settings
CA*
on/oF
oF
Automatic calibration interlock
When this function is active, calibration will not be performed
PP
on/oF
oF
Simple remote control programming
interlock
When this function is active, simple remote control programming is disabled
ZP
on/oF
oF
Remote programming of remote con-
trols interlock
When this function is active, remote programming of remote controls is disabled
9
LS
nc/no
nc
Limit input type setting
Can be used to set the type of limit switches that are used – normally open or normally closed
10
Er
Error counter
Records errors
EP
0, …, 9999
-
Overload counter
Records all stops caused by the triggering of the overcurrent safety device
EZ
0, …, 9999
-
Short-circuit counter
Records all motor short-circuits
11
LC
Cycle counter
Records cycles
cc
0, …, 999999
-
Closing counter
Records all closing cycles of the gate
co
0, …, 999999
-
Opening counter
Records all opening cycles of the gate
12
Pn
0000, …, 9999
1234
Change installer code
To change the installer code, the new installer code has to be entered twice
13
FA
Restore factory settings
To restore the factory settings, press the OK button 5 times.
14
oS*
on/oF
oF
Housing estate function
This function enables one transmitter to take over control of the controller unit for a short period
of time.
15
PF
1, ..., 99*
-
Number of programmable
transmitters
Shows the number of transmitters that can be programmed. 5x OK removes all stored transmitters
16
Lo
Slow-down area adjustment
This function adjusts the slow-down areas
to
5, ..., -5
0
Opening
Opening slow-down area adjustment
tc
5, ..., -5
0
Closing
Closing slow-down area adjustment
*This function requires the administrator code to be entered
EN
8
IIiO/AWso2018/06/2018/ID-97354
+
Technical documentation and description
Assembly and Operating Instructions
– Drive unit for gates AWso2018