Operation Manual 12./07                                              WISI Communications GmbH & Co. KG

 

Page 8 of 32 

To make modifications to settings, click into the corresponding edit box, alter the value and 
then click on the “Submit” button located on the upper left corner of the HTML page. The 
scrambler will then process the modifications. It will possibly limit some values 
automatically, so they remain in the allowed operating range. 
The status pages, like shown above, do not have a “Submit” button, but a button named 
“Refresh”. You click on this button, to refresh the contents of the status variables. 
The scrambler presents information to the administrator mainly using tables. These tables 
either have 3 or 6 columns. The first column contains a short name of the parameter presented 
in this row. The last column usually contains a short description of the parameter, it may be 
empty, if there is no description available. In between the short parameter name and the 
description is the data field, that contains the content of the parameter. Some tables present 
only one data column, other present 4 data columns to the administrator. 

 

3.1 Input fields 

 

Each input field has a specific data format: 
 

Numeric input fields

: The scrambler accepts both hexadecimal numbers (Starting with “0x”) 

and decimal numbers in numeric data fields. Numeric input fields are for example used to 
define port numbers. Acceptable numbers are for example: 
 
0x201 
513 
0xFFFFFF00 

 

The scrambler will present the number in numeric fields either as decimal or as hexadecimal 
values, depending on whatever is suitable for this input field. For example: Port numbers are 
usually decimal, while the CAS-ID is presented as a hex value. Independent of the preferred 
presentation, you can always enter hex. or dec. values in numeric input fields. 
 

IP address input field

: The scrambler accepts an IP address in the format “a.b.c.d” here. For 

example: 
 
172.29.0.130 
 

Hexadecimal string input fields

: The scrambler accepts a string of characters “0…

9” and 

“A..F” and “a…

f” 

without 

a leading “0x”. While numeric input fields only accept values, that 

fit into 32Bit variables (or less), the hexadecimal string input fields accept a much longer 
string of hexadecimal values. The hexadecimal string input fields are (for example) used to 
define “access criteria” and private data to be inserted into the CAT (for example). Example: 
 
A076B300005F 
 

String input fields

: The scrambler accepts a string of characters. String input fields are for 

example used for naming Scrambling Control Groups. 
Although many values take effect immediately, some values can only be applied after a reboot 
and some will take effect only after a transponder scan. 

 
 
 
 
 

Содержание OT 32

Страница 1: ...Operation Manual OT 32 Dual DVB Scrambler 044 137...

Страница 2: ...5 ASI IO Status Page 11 3 6 Misc Settings Page 12 3 7 ECMG Settings Page 13 3 8 ECMG Status Page 14 3 9 EMMG Settings Page 14 3 10 Detailed EMMG Status Page 15 3 11 EIS Settings Page 16 3 12 Detailed...

Страница 3: ...l the unit directly above or in the vicinity of radiators or heating systems where it would be subjected to thermal radiation or oil vapours Ventilation slots Do not cover the ventilation slots Moistu...

Страница 4: ...nctions z Stand alone Scrambler for DVB transport stream signals z Scrambling to selected programs or transport stream SPTS MPTS z Injecting of ECM and EMM from the CAS system into the transportstream...

Страница 5: ...ASI FUSE T2A 250 VAC OFF ON P O W E R Ethernet ASI in 6 7 8 230 VAC ASI trough ASI out 1 ASI out 2 Ethernet ASI in 10 11 ASI trough ASI out 1 ASI out 2 9 Figure 2 1 Stand alone scrambler back panel in...

Страница 6: ...nd IP address However its not necessary to compute the IP address to configure the scrambler first time The scrambler supports a proprietary interface called BCMD interface that allows configuration u...

Страница 7: ...ified by the MAC address 00 11 to 172 29 0 130 scrcmd mac 00 11 22 33 44 55 ip 172 29 0 130 mask 255 255 0 0 reboot Identify the physical scrambler visually by its MAC address The command causes the s...

Страница 8: ...ace It will automatically show if you access the scrambler or if you click on Status This page shows version numbers and an overall description of the scrambler status The example below shows the scra...

Страница 9: ...al numbers Starting with 0x and decimal numbers in numeric data fields Numeric input fields are for example used to define port numbers Acceptable numbers are for example 0x201 513 0xFFFFFF00 The scra...

Страница 10: ...ambler in an erroneous state because there is no transport stream present on the ASI input connector The Status page contains links that lead to status pages of some functional units of the scrambler...

Страница 11: ...ty INFO informational ERROR error condition The functional unit of the scrambler that caused the event A message describing the event The Detailed Event Log consists of multiple pages You navigate thi...

Страница 12: ...Number of times the input fifo of the scrambler overflowed Input null packet rate Number of null transport stream packets PID 0x1FFF per second arriving on the ASI input Queued inserted packet rate Nu...

Страница 13: ...M SS You have to set the current date and time only if you plan to use activation times in Scrambling Control Groups Protocol Version Selects the ECMG protocol to be used 2 or 3 Default CP Duration Th...

Страница 14: ...ttached If one is connected only you are running your system with one CAS and without backup If you have eight ECMGs attached you are running your system with four CAS and one backup for every CAS Eve...

Страница 15: ...e scrambler and ECMG agreed on using See the DVB SimulCrypt specification for a detailed description of the meaning of each parameter 3 9 EMMG Settings Page The scrambler is capable of being connected...

Страница 16: ...o a physical transport stream being attached to the scrambler at the desired rate It s the responsibility of the headend administrator to ensure that there are enough null packets in the transportstre...

Страница 17: ...Page The EIS is an external software component that defines Scrambling Control Groups It connects to the scrambler using TCP IP The scrambler will listen on the specific port for message of the EIS If...

Страница 18: ...in the menu bar 3 12 Detailed EIS Status Page The EIS status page lets you check the communication between the EIS and the scrambler 3 13 Private PSI CAT PMT Data Page The scrambler inserts private P...

Страница 19: ...administrator to define PID ranges to be used for placing ECM and EMM PID s The scrambler supports up to 4 ECM generators and up to 256 Scrambling Control Groups Therefore the scrambler needs up to 10...

Страница 20: ...e page will be update automatically every 5 seconds and notify you about the scanning progress If the web browser does not automatically update the page every 5 seconds you have to manually click on S...

Страница 21: ...ason of the failure If everything works well the scrambler will present a list of services like shown in the example below Please note Scanning is an important process because in the case of a success...

Страница 22: ...es in the menu bar or on the here link to get to the Services page Its not possible to define Scrambling Control Groups before you successful scanned a transponder If there are services scanned but no...

Страница 23: ...time indicates that the SCG is currently active does scramble content The date time in addition to active indicates the activation time when the scrambling started You may click on the active codewor...

Страница 24: ...fined by the EIS or SCG s defined manually by the web browser interface Although both kinds of Scrambling Control Groups are handled the same way the name of SCG s provisioned by the EIS begins with E...

Страница 25: ...MM SS Until this time the SCG will be marked as pending in the Scrambling Control Group List If you leave this field empty no activation time will be defined and the Scrambling Control Group will be a...

Страница 26: ...would check all component check boxes of the service If you want to scramble single components only uncheck the box left to the service name and check the appropriate boxes to the left of the componen...

Страница 27: ...CG you just have to clear all contents of all access criteria input fields and then click on the Submit button You may enter an activation time to schedule the deprovisioning in the future After proce...

Страница 28: ...the reboot However if you are using the Activation time feature of the scrambler you have to manually adjust the current date time after a reboot in the Misc Settings to setup the exact date time 3 23...

Страница 29: ...munications GmbH Co KG Click on the button to destroy all temporary unsaved changes and reboot the scrambler using the settings currently stored in the flash memory All changes made since the last reb...

Страница 30: ...z Deterministic Jitter 10 Random Jitter 8 Control Interface 100Base T Ethernet Userinterface 1 Web based Userinterface 2 Command Line Monitoring and Alarm SNMPv2c Applicable standards ETSI TR 102 035...

Страница 31: ...Operation Manual 12 07 WISI Communications GmbH Co KG Page 30 of 32 12 0 V 8 500 mA DC max Power consumption W Operating temperatur range 5 C to 45 C Nominal temperatur range 15 C to 35 C...

Страница 32: ...Modifications reserved WISI cannot be held liable for any printing error a link to the future Phone 49 7233 66 280 Fax 66 350 http www wisi de P O BOX 1220 75219 Niefern Oeschelbronn Germany Empfangs...

Отзывы: