connection
14_
connection
When the resistance value of copper wire is at [20°C(68°F)]
Copper wire size (AWG)
#24 (0.22mm
2
)
#22 (0.33mm
2
)
#20 (0.52mm
2
)
#18 (0.83mm
2
)
Resistance value(
Ω
/m)
0.078
0.050
0.030
0.018
Voltage Drop (V/m)
0.028
0.018
0.011
0.006
y
As shown in the table above, voltage decreases as the wire gets longer.
Therefore use of an excessively long adaptor output line for connection to the cam-
era may affect the performance of the camera.
❈
Standard voltage for camera operation : DC 12V±10%
❈
There may be some deviation in voltage drop depending on the type of wire and the
manufacturer.
M
`
Be sure to connect power only after all the installation is complete.
CONTROL VIA RS-485 INTERFACE
The camera can be controlled by using external controllers like a Remote controller. (RS-
485 Communication)
(1) To control by PC
Connect the RS-485 control port of the camera and the serial cable through an RS-485
converter.
Example) PC Serial Port
Serial Cable
RS-485 Converter
Camera RS-485 Control
Port.
(2) To control using a DVR or System Controller
Connect the RS-485 cable (TRX+, TRX-) to the connection port of the 485 control board
that is connected to the DVR or System Controller.
485 Control Board Connection Port
RS-485 Control Port
(+) CONNECTION TERMINAL (TRX+)
485+
(-) CONNECTION TERMINAL (TRX-)
485-
* RS-485 Communication establishment initial value
Item
Camera ID
BAUD RATE
UART MODE
RET PKT
Initial value
1
9600
8-NONE-1
ENABLE
M
`
To control the camera by constructing an additional controller, use the Samsung-T/E,
Pelco-D/P, Panasonic, Bosch, AD, Vicon, Honeywell.