background image

 

 

 

 

 

 

O p e r a t i n g  i n s t r u c t i o n s 

 

Pneumatic lifting device 

for prefabricated glass and facade elements 

 
 

OKTOPUS

®

 GL-R600 

 
 
 

Serial number: _______________ 

 
 

Technical documentation 

1 98 900 002 a 

08/2010 

This technical documentation corresponds to the state as per the date of issue. 

 
 
 

WIRTH GMBH 

INSTALLATION SYSTEMS DIVISION 

Brehnaer Straße 1 

D-06188 Landsberg 

Phone +49 (0) 34 602 / 70 88 - 0 

Fax +49 (0) 34 602 / 70 88 - 111 

www.wirth-gmbh.com

 

Original instructions 
Protected according to ISO 16016 

Содержание OKTOPUS GL-R600

Страница 1: ..._____________ Technical documentation 1 98 900 002 a 08 2010 This technical documentation corresponds to the state as per the date of issue WIRTH GMBH INSTALLATION SYSTEMS DIVISION Brehnaer Stra e 1 D...

Страница 2: ...3 5 2 Handling of glass and facade elements in vertical positions 17 3 5 3 Rotating a load hanging in a vertical position with the OKTOPUS GL R600 18 with crane arm 3 5 4 Rotating a load hanging in a...

Страница 3: ...device OKTOPUS GL R600 with guide ring 11 Fig 6 Charge indicator 13 Fig 7 Vacuum gauge 14 Fig 8 Control panel 15 Fig 9 OKTOPUS GL R600 with glass element 17 Fig 10 OKTOPUS GL R600 with glass element...

Страница 4: ...e Working Load 300 kg 4 suction cups 400 mm 600 kg 8 suction cups 400 mm CE mark as per EC declaration of conformity Appendix 3 Short summary of safety instructions on every device as per Appendix 2 T...

Страница 5: ...iance with the instructions and information for proper and safe use of the device provided in the operating instructions is a prerequisite for the manufacturer s war ranties during the warranty period...

Страница 6: ...n wind strengths of less than 36 km h else the load is endangered of swinging uncontrollably 12 Check the suction pads daily for damage if necessary replace with new pads 13 Clean the suction surfaces...

Страница 7: ...battery vacuum gauges suc tion cups red warning light green signal light acoustic alarm manual control depending on the operating conditions however at least annually inspection by a qualified expert...

Страница 8: ...Operating Instructions OKTOPUS GL R600 Technical documentation 1 98 900 002 a Page 8 of 26 Test card in accordance with Annex 4 Beware of suspended load Beware of batteries Test card General notice...

Страница 9: ...1 base frame with a centrally mounted rotating and swivelling crane arm OKTOPUS GL R600 with extension arms see Fig 2 base frame with a centrally mounted rotating and swivelling crane arm 4 items of e...

Страница 10: ...6 Fig 2 OKTOPUS GL R600 with crane arm and extension arms Fig 3 OKTOPUS GL R600 with guide ring 1 Crane eye 2 Crane arm 3 Release Swivelling 4 Swivel joint 5 Release Rotating 6 Extension arm with suc...

Страница 11: ...e ring The use of the load carrying attachment system OKTOPUS offers the following benefits dur ing the assembly of large sized glass and facade elements faster more rational and more efficient assemb...

Страница 12: ...d the performance data and op erating conditions of the employed crane and site conditions Furthermore it is to be made sure that the elements which should be processed are sufficiently stable in itse...

Страница 13: ...he battery In order to monitor the charging status of the battery the charge indicator provides you with the following information In case of a discharge of ca 70 the LED on the extreme left of the di...

Страница 14: ...constantly indi cated on the two vacuum gauges Fig 7 The green scale range is the permissible working range from 0 65 bar to 0 9 bar Fig 7 Vacuum gauge During operation the vacuum is monitored by two...

Страница 15: ...ION Check the charge level of the battery on the charge indicator the unit is ready for operation when the yellow LEDs lights up if the left hand yellow LED flash and or the red LED lights up alarm is...

Страница 16: ...PUS GL R600 to the elements Place the OKTOPUS on the topmost element Never attempt to lift a lying load if the pivoting of the crane arm is latched Place the OKTOPUS above the centre of mass 5 cm of t...

Страница 17: ...stand perpen dicularly Push the switch SUCTION RELEASE toward SUCTION see Fig 8 After the warning light and the horn have both gone out and the vacuum gauge indi cates that the working range has been...

Страница 18: ...does not hit anything during turning Unlock the release Rotating see Fig 11 and turn the load into the required position Afterwards make sure the release handle catches hold again The rotational axis...

Страница 19: ...ilting of the load In order to swivel the load from a vertical into a horizontal position at least 3 persons are needed Two persons have to secure and guide the load the third person has to operate th...

Страница 20: ...ven surface suction cups pointing down In case the guide ring is assembled dismantle it as follows Remove the special screws of two adjoining roller Push the two loose rollers away from the supporting...

Страница 21: ...hose couplings of the same color Make sure that all locking bolts are always completely located by the clip pins certified of the manufacturer The disassembly of the extension arms takes place in reve...

Страница 22: ...sing of the OKTOPUS Before performing any repair or servicing work on the OKTOPUS switch the unit off For it turn the main switch to the OFF position Only replace defective components with original sp...

Страница 23: ...pads the hoses if necessary tighten the screws or replace the hoses the vacuum gauges The vacuum pump runs fully oil free The robust design permit almost maintenance free op eration The intrusion of d...

Страница 24: ...g 16 Fig 16 Battery charger Never use a different charger to charge the battery The batteries has to be charged as follows Switch off the OKTOPUS For it push the switch SUCTION RELEASE to RE LEASE see...

Страница 25: ...ad gel batteries the charging instructions have to be complied exactly In order to prevent a destruction of the battery caused by deep discharging a permanent connection to the charger which has to be...

Страница 26: ...removed finish working with the OKTOPUS immedi ately After any elements which might be drawn have been detached the OKTOPUS has to be secured against further use If the fault cannot be remedied stop w...

Отзывы: