Page 17 of 26
Fig. 9:
OKTOPUS
®
GL-R600 with
Fig. 10: OKTOPUS
®
GL-R600 with glass
glass element
element and extension arms
3.5.2 Handling of glass and facade elements in vertical positions
⇒
Move the crane with the mounted OKTOPUS
®
GL-R600 to the elements. Place the
OKTOPUS
®
on the topmost element.
⇒
Place the OKTOPUS
®
on or above the centre of mass of the load (max.
±
5 cm).
In order to avoid an unintentional rotation, it must be ensured that the
unlocking lever “Rotating” (see Fig. 11) is engaged. The unlocking lever
“Swivelling” must be disengaged and the crane arm must stand perpen-
dicularly!
⇒
Push the switch SUCTION / RELEASE toward SUCTION (see Fig. 8).
⇒
After the warning light and the horn have both gone out and the vacuum gauge indi-
cates that the working range has been reached (see Fig. 7) and you have made sure,
that no one is present in the danger area, you can lift the load.
⇒
Only lift the load as high as necessary!
⇒
After the element has been placed at the assembly location, it has to be fastened com-
pletely!
⇒
After that the building elements are detached. For release raise the switch SUCTION /
RELEASE somewhat and push it toward RELEASE. The raising of the switch is an ad-
ditional safety device against unintentional faulty operation.