TextAlert
IV
User Manual
•
Verify that there is airtime on the SIM and it is able to send a SMS message when
inserted in a cell phone.
•
Verify that the SIM card is inserted correctly (SIM holder is locked in place).
•
If you are in a low GSM cell phone network coverage area then TA
IV
may not have
sufficient GSM signal to register with the Network provider. Please contact your
WirelessAlert agent for details of the 3dBi GSM antenna to improve the signal and
allow for sufficient network connection.
•
If booting failure persists, please contact your WirelessAlert Agent or send an email
to:
8 Linking Sensors and Remotes
Please note:
The TA
IV
kit includes one indoor PIR sensor and one magnetic door contact
sensor. Details of how to set up these two devices for use with TA
IV
are listed in
Appendix
1
. For details of use of other types of sensor with TA
IV
, please refer to user manual
included with the respective sensor.
There are 16 zones in total for adding (linking) sensors and remotes onto TA
IV
. Some of
these zones may have already been coded during factory testing. To ensure all 16 zones
are available for use, please factory reset the TA
IV
before linking remotes and or sensors,
to remove any factory settings. Press and hold in the RESET button. Turn on the device
using the on/off switch. After two seconds, the Status LED will illuminate red to indicate
factory reset. Wait 20 seconds for the unit to reboot before continuing with configuration as
outlined below.
Linking of sensors and remotes onto zones occurs sequentially, therefore it is important to
record exact details of the order in which you link the sensors onto the TA
IV
. Make use of a
simple table format as in Table 1 below and record the details in the SID document
(
Appendix 2
) for your particular installation.
Table 1:
Example of how to record zone configuration information when linking sensors
and or remotes onto TA
IV
. Please complete the relevant table with details of your
installation in SID document (
Appendix 2
).
Zone
Zone Description
Type of sensor / remote
DIP code
(00)
Kitchen area PIR
VA Indoor PIR
10000011
(01)
Front door
Magnetic contact switch
01000011
(02)
TV room PIR
VA Indoor PIR
00100011
(03)
Garage door
Magnetic contact switch
00010011
(04)
Tool shed PIR
VA Outdoor PIR (VA6000T)
00001011
(05)
Back door
Magnetic contact switch
00000111
(06)
Main entrance PIR
VA Indoor PIR
01111100
(07)
Office window
Magnetic contact switch
10111100
(08)
Office safe door
Magnetic contact switch
11011100
(09)
North wall beam
Solar Wireless Beam set
N/A - code is factory set
(10)
East wall beam
Solar Wireless Beam set
N/A - code is factory set
(11)
South wall beam
Solar Wireless Beam set
N/A - code is factory set
(12)
West wall beam
Solar Wireless Beam set
N/A - code is factory set
(13)
Back yard PIR
Solar Wireless PIR
N/A - code is factory set
(14)
Remote 1 Panic
Remote Keyfob
N/A - code is factory set
(15)
Remote 2 Panic
Remote Keyfob
N/A - code is factory set
8.1
Linking Sensor/s onto TA
IV
The TA
IV
has an
Away
and a
Stay
arming function. This allows user to configure the TA
IV
for two different modes of operation when linking sensors with TA
IV
zones. The zones can
Copyright InFocus Trading 111 cc, 2009
10