TextAlert
IV
User Manual
Relay contacts can also be turned on or off at any time, using a cell phone command,
giving the user an added level of control over any attached external devices.
11.7 Armed Response Radio Transmitter Connection
TA
IV
does not have dedicated terminals for connection of armed response transmitter in
the classic sense of Panic, Alarm, Open/Closed channels however, it does have an on-
board relay connector which can be used for triggering the
Alarm
channel of an armed
response radio transmitter. The
Panic
armed response channel can be triggered using a
small wireless receiver module and one or more remote keyfobs. Please contact your
WirelessAlert agent for assistance with armed response options.
12 WirelessAlert Support
If you have not managed to solve an issue by consulting your WirelessAlert agent, please
email details of your issue to:
Please include the following additional information with your email:
•
TextAlert
IV
Serial Number (printed on the bottom of the unit)
•
Network Provider: (Vodacom, MTN, etc?)
•
Low Signal Strength: (If the green signal LED flashes faster than once / sec or if it
does not flash at all (on solid) then there could be a problem?)
12.1 Technical Support Contact
For Technical Support please email:
12.2 Head Office Contact
For Sales and Agent Information please Email:
13 Copyright notice
All Information and images in this manual are copyrighted and proprietary to WirelessAlert.
The manual as a whole may be distributed and copied freely, but no partial content may be
used/copied or distributed in any way. No part of WirelessAlert products (including any
Hardware, Firmware and or Software) may be copied or reverse-engineered. WirelessAlert
reserves the right to make changes to contents of this manual, without notice, at any time.
14 Guarantee
TextAlert
IV
is guaranteed for a period of 12 months against defects in materials or
workmanship. Should your product become defective during the guarantee period it will
be repaired or replaced at the sole discretion of WirelessAlert under the following
conditions:
A: The unit and enclosure must not have been opened or otherwise tampered with. If the
enclosure of any unit has been opened at all, the guarantee will be null and void.
B: The guarantee does not cover damage resulting from excessive input voltages,
lightning, power surges or water damage. If any of these conditions are detected during
assessment, the guarantee will be null and void.
Assessment and opinion as to the status of each unit with regards to the conditions named
in “A” and “B”, above, will be at the sole discretion of WirelessAlert. This guarantee does
Copyright InFocus Trading 111 cc, 2009