Message Relay Options Window
This window is used to set global relay control actions according to the text contained in a message received on
the selected capcodes. Up to 128 actions may be set for the PDR and PSR and 80 for the PDT. Sets the action
that will occur on each of the 4 on board relays and the relays contained on the RCM2000 module (if connected) on
receipt of matched text in the message on a specified capcode.
Adding Text to Control Relays
1. Click on the "New" Button to create a list in the message relay options table.
2. Enter the new text to be matched in the specified message in the "Message Text" box.
3. Select the specified capcode whose messages will be searched to match the text in the "Message Text"
box.
4. Set the action that will occur on each of the four on board relay and the relays contained on the RCM2000
relay board.
Control Relay Options
Relays 1-4
Sets the action that will occur on each of the 4 on board relays on receipt of any message on that capcode. Relays
are Normally Open. Options are
1. Close Relay
2. Open Relay
3. Momentary Close Relay for a period (in msecs)
4. Clear by Keys - resets the relay to open on pressing any key.
Global Option Clear By Keys
If selected, any relay action initiated by any Message Text will be cancelled (reset to normal condition) by hitting
any key.
Only match at beginning
If selected only text at the beginning of the message will be matched with the target text