Connecting the PDT3000
Required Items:
1 x Serial Null Modem DB9 female-to-female cable.
1 x 12v DC Power supply rated at 0.5 amps (or greater) with 2.5mm center positive plug attached.
1. Plug the serial cable into the PC (COM1 is the default port)
2. Open PDT3P
3. Select the template appropriate to the PDT3000 that you are programming. Note: if you only have a key for
one template then PDT3P will open automatically with that template active.
4. Plug the PDT3000 into a 12-volt supply and plug in the DB9 plug into the back of the PDT3000.
{PDT3P does not read or write to the PDT3000 unless instructed to do so. It is recommended that, unless you need
to change the basic template of the PDT3000, you download the program in the unit first. Click on the "Download
From Pager" button. This will download the current settings from the PDT3000. It will also automatically select the
template that is currently loaded in the PDT3000. If you need to change the basic template of the PDT3000 do not
do a download. Just select your template, change the settings and press "Upload To Pager" (Please consult) }