Troubleshooting

  

 

Frequently

 

Asked

 

Questions

 

 

Q

:

 

Why

 

does

 

the

 

push

 

button

 

on

 

the

 

switch

 

not

 

work?

 

A

:

  

1

.

 

Check

 

whether

 

the

 

Protection

 

is

 

enabled

 

or

 

not.

 

If

 

it

 

is,

 

disable

 

the

 

protection

 

and

 

try

 

again.

 

 

 

For

 

more

 

information

 

about

 

disabling

 

the

 

protection

 

please

 

refer

 

to

 

the

 

supporting

 

command

 

classes.

 

 

2

.

 

During

 

the

 

NWI

 

and

 

the

 

inclusion/exclusion

 

process,

 

the

 

push

 

button

 

will

 

not

 

work.

 

 

3

.

 

Check

 

if

 

the

 

iPlugDim  

 

is

 

comple

t

ely

 

plugged

 

in

t

o

 

the

 

socket.

 

 

Q

:

 

I

 

can’t

 

have

 

my

 

iPlugDim 

in

c

l

u

ded

 

into

 

my

 

Z

Wave

 

network,

 

what

 

am

 

I

 

doing

 

wron

g

?

 

A

:

  

1

.

 

Is

 

the

 

controller

 

ready

 

to

 

include

 

any

 

device

 

into

 

the

 

Z

Wave

 

network?

 

If

 

the

 

controller

 

is

 

not

 

in

  

 

Include

 

or

 

exclude

 

mode,

 

the

 

iPlugDim 

cannot

 

be

 

in

c

lude

d

 

or

 

excluded.

 

2

.

 

The

 

iPlugDim

 

is

 

alre

a

dy

 

included

 

into

 

a

 

Z

Wave

 

ne

t

wo

r

k.

 

Exclu

d

e

 

the

 

swit

c

h

 

an

d

 

try

 

to

 

include

 

it

 

again.

 

 

Q

:

 

Why

 

does

 

the

 

indicator

 

light

 

not

 

work?

 

A

:

  

1

.

 

Check

 

if

 

the

 iPlugDim 

is

 

ful

l

y

 

plugged

 

into

 

a

 

socke

t

.

 

Th

e

 

ind

i

cato

r

 

light

 

will

 

not

 

work

 

if

 

there

 

is

 

no

 

power

 

supplied

 

to

 

the

 

iPlugDim.

  

2

.

 

The

 

Indicator

 

light

 

is

 

only

 

on

 

when

 

the

 

iPlugDim is loaded. Plug in a load.

 

 

Содержание iPlugDim

Страница 1: ...nd hold the push button for 4 seconds and release to start the inclusion or exclusion process indication mode Ready for learn mode 3 The product will start NWI automatically after unsuccessful normal inclusion Manual control Press and release the push button of the iPlugDim to switch on off the load of socket press and hold the push button to dim the load of the socket Remote control The iPlugDim ...

Страница 2: ...place of purchase Do not clean the product with any liquid Indoor use only Technical details Absolute min max voltage 220V 50Hz Maximum peak resistive load 500W Frequency range 868 42 MHz Wireless Range Up to 30m line of sight Storage temperature 5 C to 65 C Storage humidity 10 to 70 Operating temperature 0 C to 50 C Operating humidity 30 to 80 Supporting Command Classes Basic type BASIC_TYPE_ROUT...

Страница 3: ...rom the network When the exclude initiator and a slave initiator are activated simultaneously it will result in the slave being excluded from the network and reset to Node ID zero Even if the slave was not part of the network it will still be reset by this action Z Wave compatibility Because this is a Z Wave device it means it can co operate with other Z Wave devices of other manufacturers It can ...

Страница 4: ...im With CONFIGURATION_SET different configuration parameters can be set These parameters can be changed 0 not used 1 Set to default Description Set all config values to default values factory settings Read more in chapter Configuration Reset Size 1 byte Param1 All values 0x00 0xFF except for 0x55 can be used to default all the configuration params Param2 3 4 not used ...

Страница 5: ... supported grouping identifier is ignored in all cases class 0x73 COMMAND_CLASS_POWERLEVEL The Powerlevel Command Class defines the RF transmitting power This command is used to test the connectivity of a network The Command makes it possible for supporting controllers to SET GET the RF transmitting power level of a node and test specific links between nodes class 0x75 COMMAND_CLASS_PROTECTION The...

Страница 6: ... off functionality 0x01 is excluded from the all on but not the all off 0x02 is excluded from the all off but not the all on 0x03 All on and all off are both included Configuration Reset The iPlugDim Supports a configuration resets function Configuration reset means All configuration values are defaulted This function can be activated by sending a configuration set frame CONFIGURATION_SET Paramete...

Страница 7: ...s completely plugged into the socket Q I can t have my iPlugDim included into my Z Wave network what am I doing wrong A 1 Is the controller ready to include any device into the Z Wave network If the controller is not in Include or exclude mode the iPlugDim cannot be included or excluded 2 The iPlugDim is already included into a Z Wave network Exclude the switch and try to include it again Q Why do...

Отзывы: